§1033.501 General provisions.
(a) Except as specified in this subpart, use the equipment and procedures for compression-ignition engines in 40 CFR part 1065 to determine whether your locomotives meet the duty-cycle emission standards in §1033.101. Use the applicable duty cycles specified in this subpart. Measure emissions of all the pollutants we regulate in §1033.101 plus CO2. Measure N2O, and CH4 as described in §1033.235. The general test procedure is the procedure specified in 40 CFR part 1065 for steady-state discrete-mode cycles. However, if you use the optional ramped modal cycle in §1033.520, follow the procedures for ramped modal testing in 40 CFR part 1065. The following exceptions from the 1065 procedures apply:
(1) You must average power and emissions over the sampling periods specified in this subpart for both discrete-mode testing and ramped modal testing.
(2) The test cycle is considered to be steady-state with respect to operator demand rather than engine speed and load.
(3) The following provisions apply for engine mapping, duty-cycle generation, and cycle validation to account for the fact that locomotive operation and locomotive duty cycles are based on operator demand from locomotive notch settings, not on target values for engine speed and load:
(i) The provisions related to engine mapping, duty-cycle generation, and cycle validation in 40 CFR 1065.510, 1065.512, and 1065.514 do not apply for testing complete locomotives.
(ii) The provisions related to engine mapping and duty-cycle generation in 40 CFR 1065.510 and 1065.512 are not required for testing with an engine dynamometer; however, the cycle validation criteria of 40 CFR 1065.514 apply for such testing. Demonstrate compliance with cycle validation criteria based on manufacturer-declared values for maximum torque, maximum power, and maximum test speed, or determine these values from an engine map generated according to 40 CFR 1065.510. If you test using a ramped-modal cycle, you may perform cycle validation over all the test intervals together.
(4) If you perform discrete-mode testing and use only one batch fuel measurement to determine your mean raw exhaust flow rate, you must target a constant sample flow rate over the mode. Verify proportional sampling as described in 40 CFR 1065.545 using the mean raw exhaust molar flow rate paired with each recorded sample flow rate.
(5) If you perform discrete-mode testing by grouping the modes in the same manner as the test intervals of the ramped modal cycle using three different dilution settings for the groups, as allowed in §1033.515(c)(5)(ii), you may verify proportional sampling over each group instead of each discrete mode.
(b) You may use special or alternate procedures to the extent we allow as them under 40 CFR 1065.10. In some cases, we allow you to use procedures that are less precise or less accurate than the specified procedures if they do not affect your ability to show that your locomotives comply with the applicable emission standards. This generally requires emission levels to be far enough below the applicable emission standards so that any errors caused by greater imprecision or inaccuracy do not affect your ability to state unconditionally that the locomotives meet all applicable emission standards.
(c) This part allows (with certain limits) testing of either a complete locomotive or a separate uninstalled engine. When testing a locomotive, you must test the complete locomotive in its in-use configuration, except that you may disconnect the power output and fuel input for the purpose of testing. To calculate power from measured alternator/generator output, use an alternator/generator efficiency curve that varies with speed/load, consistent with good engineering judgment.
(d) Unless smoke standards do not apply for your locomotives or the testing requirement is waived, measure smoke emissions using the procedures in §1033.525.
(e) Use the applicable fuel listed in 40 CFR part 1065, subpart H, to perform valid tests.
(1) For diesel-fueled locomotives, use the appropriate diesel fuel specified in 40 CFR part 1065, subpart H, for emission testing. The applicable diesel test fuel is either the ultra low-sulfur diesel or low-sulfur diesel fuel, as specified in §1033.101. Identify the test fuel in your application for certification and ensure that the fuel inlet label is consistent with your selection of the test fuel (see §§1033.101 and 1033.135).
(2) You may ask to use as a test fuel commercially available diesel fuel similar but not identical to the applicable fuel specified in 40 CFR part 1065, subpart H; we will approve your request if you show us that it does not affect your ability to demonstrate compliance with the applicable emission standards. If your locomotive uses sulfur-sensitive technology, you may not use an in-use fuel that has a lower sulfur content than the range specified for the otherwise applicable test fuel in 40 CFR part 1065. If your locomotive does not use sulfur-sensitive technology, we may allow you to use an in-use fuel that has a lower sulfur content than the range specified for the otherwise applicable test fuel in 40 CFR part 1065, but may require that you correct PM emissions to account for the sulfur differences.
(3) For service accumulation, use the test fuel or any commercially available fuel that is representative of the fuel that in-use locomotives will use.
(f) See §1033.505 for information about allowable ambient testing conditions for testing.
(g) This subpart is addressed to you as a manufacturer/remanufacturer, but it applies equally to anyone who does testing for you, and to us when we perform testing to determine if your locomotives meet emission standards.
(h) We may also perform other testing as allowed by the Clean Air Act.
(i) For passenger locomotives that can generate hotel power from the main propulsion engine, the locomotive must comply with the emission standards when in non-hotel setting. For hotel mode, the locomotive is subject to the notch cap provisions of §1033.101 and the defeat device prohibition of §1033.115.
(j) The following provisions apply for locomotives using aftertreatment technology with infrequent regeneration events that may occur during testing:
(1) Adjust measured emissions to account for aftertreatment technology with infrequent regeneration as described in §1033.535.
(2) Invalidate a smoke test if active regeneration starts to occur during the test.
[73 FR 37197, June 30, 2008, as amended at 74 FR 56508, Oct. 30, 2008; 75 FR 22984, Apr. 30, 2010; 81 FR 74006, Oct. 25, 2016]
§1033.505 Ambient conditions.
This section specifies the allowable ambient conditions (including temperature and pressure) under which testing may be performed to determine compliance with the emission standards of §1068.101. Manufacturers/remanufacturers may ask to perform testing at conditions other than those allowed by this section. We will allow such testing provided it does not affect your ability to demonstrate compliance with the applicable standards. See §§1033.101 and 1033.115 for more information about the requirements that apply at other conditions.
(a) Temperature.(1) Testing may be performed with ambient temperatures from 15.5°C (60°F) to 40.5°C (105°F). Do not correct emissions for temperature effects within this range.
(2) It is presumed that combustion air will be drawn from the ambient air. Thus, the ambient temperature limits of this paragraph (a) apply for intake air upstream of the engine. If you do not draw combustion air from the ambient air, use good engineering judgment to ensure that any temperature difference (between the ambient air and combustion air) does not cause the emission measurement to be unrepresentative of in-use emissions.
(3) If we allow you to perform testing at ambient temperatures below 15.5°C, you must correct NOX emissions for temperature effects, consistent with good engineering judgment. For example, if the intake air temperature (at the manifold) is lower at the test temperature than it would be for equivalent operation at an ambient temperature of 15.5°C, you generally will need to adjust your measured NOX emissions to account for the effect of the lower intake air temperature. However, if you maintain a constant manifold air temperature, you will generally not need to correct emissions.
(b) Altitude/pressure. Testing may be performed with ambient pressures from 88.000 kPa (26.0 in Hg) to 103.325 kPa (30.5 in Hg). This is intended to correspond to altitudes up to 4000 feet above sea level. Do not correct emissions for pressure effects within this range.
(c) Humidity. Testing may be performed with any ambient humidity level. Correct NOX emissions as specified in 40 CFR 1065.670. Do not correct any other emissions for humidity effects.
(d) Wind. If you test outdoors, use good engineering judgment to ensure that excessive wind does not affect your emission measurements. Winds are excessive if they disturb the size, shape, or location of the exhaust plume in the region where exhaust samples are drawn or where the smoke plume is measured, or otherwise cause any dilution of the exhaust. Tests may be conducted if wind shielding is placed adjacent to the exhaust plume to prevent bending, dispersion, or any other distortion of the exhaust plume as it passes through the optical unit or through the sample probe.
[73 FR 37197, June 30, 2008, as amended at 75 FR 22984, Apr. 30, 2010]
§1033.510 Auxiliary power units.
If your locomotive is equipped with an auxiliary power unit (APU) that operates during an idle shutdown mode, you must account for the APU's emissions rates as specified in this section, unless the APU is part of an AESS system that was certified separately from the rest of the locomotive. This section does not apply for auxiliary engines that only provide hotel power.
(a) Adjust the locomotive main engine's idle emission rate (g/hr) as specified in §1033.530. Add the APU emission rate (g/hr) that you determine under paragraph (b) of this section. Use the locomotive main engine's idle power as specified in §1033.530.
(b) Determine the representative emission rate for the APU using one of the following methods.
(1) Installed APU tested separately. If you separately measure emission rates (g/hr) for each pollutant from the APU installed in the locomotive, you may use the measured emissions rates (g/hr) as the locomotive's idle emissions rates when the locomotive is shutdown and the APU is operating. For all testing other than in-use testing, apply appropriate deterioration factors to the measured emission rates. You may ask to carryover APU emission data for a previous test, or use data for the same APU installed on locomotives in another engine family.
(2) Uninstalled APU tested separately. If you separately measure emission rates (g/hr) over an appropriate duty-cycle for each pollutant from the APU when it is not installed in the locomotive, you may use the measured emissions rates (g/hr) as the locomotive's idle emissions rates when the locomotive is shutdown and the APU is operating. For the purpose of this paragraph (b)(2), an appropriate duty-cycle is one that approximates the APU engine's cycle-weighted power when operating in the locomotive. Apply appropriate deterioration factors to the measured emission rates. You may ask to carryover APU emission data for a previous test, or use data for the same APU installed on locomotives in another engine family.
(3) APU engine certification data. If the engine used for the APU has been certified to EPA emission standards you may calculate the APU's emissions based upon existing EPA-certification information about the APU's engine. In this case, calculate the APU's emissions as follows:
(i) For each pollutant determine the brake-specific standard/FEL to which the APU engine was originally EPA-certified.
(ii) Determine the APU engine's cycle-weighted power when operating in the locomotive.
(iii) Multiply each of the APU's applicable brake-specific standards/FELs by the APU engine's cycle-weighted power. The results are the APU's emissions rates (in g/hr).
(iv) Use these emissions rates as the locomotive's idle emissions rates when the locomotive is shutdown and the APU is running. Do not apply a deterioration factor to these values.
(4) Other. You may ask us to approve an alternative means to account for APU emissions.
[73 FR 37197, June 30, 2008, as amended at 73 FR 59190, Oct. 8, 2008]
§1033.515 Discrete-mode steady-state emission tests of locomotives and locomotive engines.
This section describes how to test locomotives at each notch setting so that emissions can be weighted according to either the line-haul duty cycle or the switch duty cycle. The locomotive test cycle consists of a warm-up followed by a sequence of nominally steady-state discrete test modes, as described in Table 1 to this section. The test modes are steady-state with respect to operator demand, which is the notch setting for the locomotive. Engine speeds and loads are not necessarily steady-state.
(a) Follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning which is included as engine warm-up). You may operate the engine in any way you choose to warm it up prior to beginning the sample preconditioning specified in 40 CFR part 1065.
(b) Begin the test by operating the locomotive over the pre-test portion of the cycle specified in Table 1 to this section. For locomotives not equipped with catalysts, you may begin the test as soon as the engine reaches its lowest idle setting. For catalyst-equipped locomotives, you may begin the test in normal idle mode if the engine does not reach its lowest idle setting within 15 minutes. If you do start in normal idle, run the low idle mode after normal idle, then resume the specified mode sequence (without repeating the normal idle mode).
(c) Measure emissions during the rest of the test cycle.
(1) Each test mode begins when the operator demand to the locomotive or engine is set to the applicable notch setting.
(2) Start measuring gaseous emissions, power, and fuel consumption at the start of the test mode A and continue until the completion of test mode 8. You may zero and span analyzers between modes (or take other actions consistent with good engineering judgment).
(i) The sample period over which emissions for the mode are averaged generally begins when the operator demand is changed to start the test mode and ends within 5 seconds of the minimum sampling time for the test mode is reached. However, you need to shift the sampling period to account for sample system residence times. Follow the provisions of 40 CFR 1065.308 and 1065.309 to time align emission and work measurements.
(ii) The sample period is 300 seconds for all test modes except mode 8. The sample period for test mode 8 is 600 seconds.
(3) If gaseous emissions are sampled using a batch-sampling method, begin proportional sampling at the beginning of each sampling period and terminate sampling once the minimum time in each test mode is reached, ±5 seconds.
(4) If applicable, begin the smoke test at the start of the test mode A. Continue collecting smoke data until the completion of test mode 8. You may perform smoke measurements independent of criteria pollutant measurements by repeating the test over the duty cycle. If you choose this option, the minimum time-in-notch is 3.0 minutes for duty cycles in which only smoke is measured. Refer to §1033.101 to determine applicability of smoke testing and §1033.525 for details on how to conduct a smoke test.
(5) Begin proportional sampling of PM emissions at the beginning of each sampling period and terminate sampling within ±5 seconds of the specified time in each test mode. If the PM sample is not sufficiently large, take one of the following actions consistent with good engineering judgment:
(i) Extend the sampling period up to a maximum of 15 minutes.
(ii) Group the modes in the same manner as the test intervals of the ramped modal cycle and use three different dilution settings for the groups. Use one setting for both idle modes, one for dynamic brake through Notch 5, and one for Notch 6 through Notch 8. For each group, ensure that the mode with the highest exhaust flow (typically normal idle, Notch 5, and Notch 8) meets the criteria for minimum dilution ratio in 40 CFR part 1065.
(6) Proceed through each test mode in the order specified in Table 1 to this section until the locomotive test cycle is completed.
(7) At the end of each numbered test mode, you may continue to operate sampling and dilution systems to allow corrections for the sampling system's response time.
(8) Following the completion of Mode 8, conduct the post sampling procedures in §1065.530. Note that cycle validation criteria do not apply to testing of complete locomotives.
Test mode | Notch setting | Time in mode (minutes) 1 | Sample averaging period for emissions 1 |
---|---|---|---|
1 The time in each notch and sample averaging period may be extended as needed to allow for collection of a sufficiently large PM sample. 2 Omit if not so equipped. 3 See paragraph (b) of this section for alternate pre-test provisions. | |||
Pre-test idle | Lowest idle setting | 10 to 15 3 | Not applicable |
A | Low idle 2 | 5 to 10 | 300 ±5 seconds |
B | Normal idle | 5 to 10 | 300 ±5 seconds |
C | Dynamic brake 2 | 5 to 10 | 300 ±5 seconds |
1 | Notch 1 | 5 to 10 | 300 ±5 seconds |
2 | Notch 2 | 5 to 10 | 300 ±5 seconds |
3 | Notch 3 | 5 to 10 | 300 ±5 seconds |
4 | Notch 4 | 5 to 10 | 300 ±5 seconds |
5 | Notch 5 | 5 to 10 | 300 ±5 seconds |
6 | Notch 6 | 5 to 10 | 300 ±5 seconds |
7 | Notch 7 | 5 to 10 | 300 ±5 seconds |
8 | Notch 8 | 10 to 15 | 600 ±5 seconds |
(d) Use one of the following approaches for sampling PM emissions during discrete-mode steady-state testing:
(1) Engines certified to a PM standard/FEL at or above 0.05 g/bhp-hr. Use a separate PM filter sample for each test mode of the locomotive test cycle according to the procedures specified in paragraph (a) through (c) of this section. You may ask to use a shorter sampling period if the total mass expected to be collected would cause unacceptably high pressure drop across the filter before reaching the end of the required sampling time. We will not allow sampling times shorter than 60 seconds. When we conduct locomotive emission tests, we will adhere to the time limits for each of the numbered modes in Table 1 to this section.
(2) Engines certified to a PM standard/FEL below 0.05 g/bhp-hr.(i) You may use separate PM filter samples for each test mode as described in paragraph (d)(1) of this section; however, we recommend that you do not. The low rate of sample filter loading will result in very long sampling times and the large number of filter samples may induce uncertainty stack-up that will lead to unacceptable PM measurement accuracy. Instead, we recommend that you measure PM emissions as specified in paragraph (d)(2)(ii) of this section.
(ii) You may use a single PM filter for sampling PM over all of the test modes of the locomotive test cycle as specified in this paragraph (d)(2). Vary the sample time to be proportional to the applicable line-haul or switch weighting factors specified in §1033.530 for each mode. The minimum sampling time for each mode is 400 seconds multiplied by the weighting factor. For example, for a mode with a weighting factor of 0.030, the minimum sampling time is 12.0 seconds. PM sampling in each mode must be proportional to engine exhaust flow as specified in 40 CFR part 1065. Begin proportional sampling of PM emissions at the beginning of each test mode as is specified in paragraph (c) of this section. End the sampling period for each test mode so that sampling times are proportional to the weighting factors for the applicable duty cycles. If necessary, you may extend the time limit for each of the test modes beyond the sampling times in Table 1 to this section to increase the sampled mass of PM emissions or to account for proper weighting of the PM emission sample over the entire cycle, using good engineering judgment.
(e) This paragraph (e) describes how to test locomotive engines when not installed in a locomotive. Note that the test procedures for dynamometer engine testing of locomotive engines are intended to produce emission measurements that are the same as emission measurements produced during testing of complete locomotives using the same engine configuration. The following requirements apply for all engine tests:
(1) Specify a second-by-second set of engine speed and load points that are representative of in-use locomotive operation for each of the set-points of the locomotive test cycle described in Table 1 to this section, including transitions from one notch to the next. This is your reference cycle for validating your cycle. You may ignore points between the end of the sampling period for one mode and the point at which you change the notch setting to begin the next mode.
(2) Keep the temperature of the air entering the engine after any charge air cooling to within 5°C of the typical intake manifold air temperature when the engine is operated in the locomotive under similar ambient conditions.
(3) Proceed as specified in paragraphs (a) through (d) of this section for testing complete locomotives.
[73 FR 37197, June 30, 2008, as amended at 73 FR 59190, Oct. 8, 2008; 74 FR 8424, Feb. 24, 2009; 75 FR 22985, Apr. 30, 2010; 81 FR 74006, Oct. 25, 2016]
§1033.520 Alternative ramped modal cycles.
(a) Locomotive testing over a ramped modal cycle is intended to improve measurement accuracy at low emission levels by allowing the use of batch sampling of PM and gaseous emissions over multiple locomotive notch settings. Ramped modal cycles combine multiple test modes of a discrete-mode steady-state into a single sample period. Time in notch is varied to be proportional to weighting factors. The ramped modal cycle for line-haul locomotives is shown in Table 1 to this section. The ramped modal cycle for switch locomotives is shown in Table 2 to this section. Both ramped modal cycles consist of a warm-up followed by three test intervals that are each weighted in a manner that maintains the duty-cycle weighting of the line-haul and switch locomotive duty cycles in §1033.530. You may use ramped modal cycle testing for any locomotives certified under this part.
(b) Ramped modal testing requires continuous gaseous analyzers and three separate PM filters (one for each test interval). You may collect a single batch sample for each test interval, but you must also measure gaseous emissions continuously to allow calculation of notch caps as required under §1033.101.
(c) You may operate the engine in any way you choose to warm it up. Then follow the provisions of 40 CFR part 1065, subpart F for general pre-test procedures (including engine and sampling system pre-conditioning).
(d) Begin the test by operating the locomotive over the pre-test portion of the cycle. For locomotives not equipped with catalysts, you may begin the test as soon as the engine reaches its lowest idle setting. For catalyst-equipped locomotives, you may begin the test in normal idle mode if the engine does not reach its lowest idle setting within 15 minutes. If you do start in normal idle, run the low idle mode after normal idle, then resume the specified mode sequence (without repeating the normal idle mode).
(e) Start the test according to 40 CFR 1065.530.
(1) Each test interval begins when operator demand is set to the first operator demand setting of each test interval of the ramped modal cycle. Each test interval ends when the time in mode is reached for the last mode in the test interval.
(2) For PM emissions (and other batch sampling), the sample period over which emissions for the test interval are averaged generally begins within 10 seconds after the operator demand is changed to start the test interval and ends within 5 seconds of the sampling time for the test mode is reached (see Table 1 to this section). You may ask to delay the start of the sample period to account for sample system residence times longer than 10 seconds.
(3) Use good engineering judgment when transitioning between test intervals.
(i) You should come as close as possible to simultaneously:
(A) Ending batch sampling of the previous test interval.
(B) Starting batch sampling of the next test interval.
(C) Changing the operator demand to the notch setting for the first mode in the next test interval.
(ii) Avoid the following:
(A) Overlapping batch sampling of the two test intervals.
(B) An unnecessarily long delay before starting the next test interval.
(iii) For example, the following sequence would generally be appropriate:
(A) End batch sampling for Interval 2 after 304 seconds in Notch 5.
(B) Switch the operator demand to Notch 6 one second later.
(C) Begin batch sampling for Interval 3 one second after switching to Notch 6.
(4) If applicable, begin the smoke test at the start of the first test interval of the applicable ramped modal cycle. Continue collecting smoke data until the completion of final test interval. You may perform smoke measurements independent of criteria pollutant measurements by rerunning the test over the duty cycle. If you choose this option, the minimum time-in-notch is 3.0 minutes for duty cycles in which only smoke is measured. Refer to §1033.101 to determine applicability of the smoke standards and §1033.525 for details on how to conduct a smoke test.
(5) Proceed through each test interval of the applicable ramped modal cycle in the order specified until the test is completed.
(6) If you must void a test interval, you may repeat it. To do so, begin with a warm engine operating at the notch setting for the last mode in the previous test interval. You do not need to repeat later test intervals if they were valid. (Note: You must report test results for all voided tests and test intervals.)
(7) Following the completion of the third test interval of the applicable ramped modal cycle, conduct the post-test sampling procedures specified in 40 CFR 1065.530.
(f) Calculate your cycle-weighted brake-specific emission rates as follows:
(1) For each test interval j:
(i) Calculate emission rates (Eij) for each pollutant i as the total mass emissions divided by the total time in the test interval.
(ii) Calculate average power (Pj) as the total work divided by the total time in the test interval.
(2) For each pollutant, calculate your cycle-weighted brake-specific emission rate using the following equation, where wj is the weighting factor for test interval j:
(g) The following tables define applicable ramped modal cycles for line-haul and switch locomotives:
RMC test interval | Weighting factor | RMC mode | Time in mode (seconds) | Notch setting |
---|---|---|---|---|
Pre-test idle | NA | NA | 600 to 900 | Lowest idle setting. 1 |
Interval 1 (Idle test) | 0.380 | A | 600 | Low Idle. 2 |
B | 600 | Normal Idle. | ||
Interval Transition | ||||
Interval 2 | 0.389 | C | 1000 | Dynamic Brake. 3 |
1 | 520 | Notch 1. | ||
2 | 520 | Notch 2. | ||
3 | 416 | Notch 3. | ||
4 | 352 | Notch 4. | ||
5 | 304 | Notch 5. | ||
Interval Transition | ||||
Interval 3 | 0.231 | 6 | 144 | Notch 6. |
7 | 111 | Notch 7. | ||
8 | 600 | Notch 8. | ||
1 See paragraph (d) of this section for alternate pre-test provisions. 2 Operate at normal idle for modes A and B if not equipped with multiple idle settings. 3 Operate at normal idle if not equipped with a dynamic brake. |
RMC test interval | Weighting factor | RMC mode | Time in mode (seconds) | Notch setting |
---|---|---|---|---|
Pre-test idle | NA | NA | 600 to 900 | Lowest idle setting. 1 |
Interval 1 (Idle test) | 0.598 | A | 600 | Low Idle. 2 |
B | 600 | Normal Idle. | ||
Interval Transition | ||||
Interval 2 | 0.377 | 1 | 868 | Notch 1. |
2 | 861 | Notch 2. | ||
3 | 406 | Notch 3. | ||
4 | 252 | Notch 4. | ||
5 | 252 | Notch 5. | ||
Interval Transition | ||||
Interval 3 | 0.025 | 6 | 1080 | Notch 6. |
7 | 144 | Notch 7. | ||
8 | 576 | Notch 8. | ||
1 See paragraph (d) of this section for alternate pre-test provisions. 2 Operate at normal idle for modes A and B if not equipped with multiple idle settings. |
[81 FR 74007, Oct. 25, 2016]
§1033.525 Smoke opacity testing.
Analyze exhaust opacity test data as follows:
(a) Measure exhaust opacity using the procedures specified in 40 CFR 1065.1125. Perform the opacity test with a continuous digital recording of smokemeter response identified by notch setting over the entire locomotive test cycle specified in §1033.515(c)(4) or §1033.520(e)(4). Measure smokemeter response in percent opacity to within one percent resolution.
(b) Calibrate the smokemeter as follows:
(1) Calibrate using neutral density filters with approximately 10, 20, and 40 percent opacity. Confirm that the opacity values for each of these reference filters are NIST-traceable within 185 days of testing, or within 370 days of testing if you consistently protect the reference filters from light exposure between tests.
(2) Before each test, remove the smokemeter from the exhaust stream, if applicable, and calibrate as follows:
(i) Zero. Adjust the smokemeter to give a zero response when there is no detectable smoke.
(ii) Linearity. Insert each of the qualified reference filters in the light path perpendicular to the axis of the light beam and adjust the smokemeter to give a result within 1 percentage point of the named value for each reference filter.
(c) Use computer analysis to evaluate percent opacity for each notch setting. Treat the start of the first idle mode as the start of the test. Each mode ends when operator demand changes for the next mode (or for the end of the test). Analyze the opacity trace using the following procedure:
(1) 3 second peak. Identify the highest opacity value over the test and integrate the highest 3 second average including that highest value.
(2) 30 second peak. Divide the test into a series of 30 second segments, advancing each segment in 1 second increments. Determine the opacity value for each segment and identify the highest opacity value from all the 30 second segments.
(3) Steady-state. Calculate the average of second-by-second values between 120 and 180 seconds after the start of each mode. For RMC modes that are less than 180 seconds, calculate the average over the last 60 seconds of the mode. Identify the highest of those steady-state values from the different modes.
(d) Determine values of standardized percent opacity, κstd, by correcting to a reference optical path length of 1 meter for comparing to the standards using the following equation:
Where:
κmeas = the value of percent opacity from paragraphs (c)(1) through (3) of this section.
lmeas = the smokemeter's optical path length in the exhaust plume, expressed to the nearest 0.01 meters.
Example:
κmeas = 14.1%
lmeas = 1.11 m
κstd = 12.8%
[88 FR 4485, Jan. 24, 2023]
§1033.530 Duty cycles and calculations.
This section describes how to apply the duty cycle to measured emission rates to calculate cycle-weighted average emission rates.
(a) Standard duty cycles and calculations. Tables 1 and 2 of this section show the duty cycle to use to calculate cycle-weighted average emission rates for locomotives equipped with two idle settings, eight propulsion notches, and at least one dynamic brake notch and tested using the Locomotive Test Cycle. Use the appropriate weighting factors for your locomotive application and calculate cycle-weighted average emissions as specified in 40 CFR part 1065, subpart G.
Notch setting | Test mode | Line-haul weighting factors | Line-haul weighting factors (no dynamic brake) | Switch weighting factors |
---|---|---|---|---|
Low Idle | A | 0.190 | 0.190 | 0.299 |
Normal Idle | B | 0.190 | 0.315 | 0.299 |
Dynamic Brake | C | 0.125 | (1) | 0.000 |
Notch 1 | 1 | 0.065 | 0.065 | 0.124 |
Notch 2 | 2 | 0.065 | 0.065 | 0.123 |
Notch 3 | 3 | 0.052 | 0.052 | 0.058 |
Notch 4 | 4 | 0.044 | 0.044 | 0.036 |
Notch 5 | 5 | 0.038 | 0.038 | 0.036 |
Notch 6 | 6 | 0.039 | 0.039 | 0.015 |
Notch 7 | 7 | 0.030 | 0.030 | 0.002 |
Notch 8 | 8 | 0.162 | 0.162 | 0.008 |
1 Not applicable. |
Notch setting | Test mode | Line-haul | Line-haul (no dynamic brake) | Switch |
---|---|---|---|---|
Normal Idle | A | 0.380 | 0.505 | 0.598 |
Dynamic Brake | C | 0.125 | (1) | 0.000 |
Notch 1 | 1 | 0.065 | 0.065 | 0.124 |
Notch 2 | 2 | 0.065 | 0.065 | 0.123 |
Notch 3 | 3 | 0.052 | 0.052 | 0.058 |
Notch 4 | 4 | 0.044 | 0.044 | 0.036 |
Notch 5 | 5 | 0.038 | 0.038 | 0.036 |
Notch 6 | 6 | 0.039 | 0.039 | 0.015 |
Notch 7 | 7 | 0.030 | 0.030 | 0.002 |
Notch 8 | 8 | 0.162 | 0.162 | 0.008 |
1 Not applicable. |
(b) Idle and dynamic brake notches. The test procedures generally require you to measure emissions at two idle settings and one dynamic brake, as follows:
(1) If your locomotive is equipped with two idle settings and one or more dynamic brake settings, measure emissions at both idle settings and the worst case dynamic brake setting, and weight the emissions as specified in the applicable table of this section. Where it is not obvious which dynamic brake setting represents worst case, do one of the following:
(i) You may measure emissions and power at each dynamic brake point and average them together.
(ii) You may measure emissions and power at the dynamic brake point with the lowest power.
(2) If your locomotive is equipped with two idle settings and is not equipped with dynamic brake, use a normal idle weighting factor of 0.315 for the line-haul cycle. If your locomotive is equipped with only one idle setting and no dynamic brake, use an idle weighting factor of 0.505 for the line-haul cycle.
(c) Nonstandard notches or no notches. If your locomotive is equipped with more or less than 8 propulsion notches, recommend an alternate test cycle based on the in-use locomotive configuration. Unless you have data demonstrating that your locomotive will be operated differently from conventional locomotives, recommend weighting factors that are consistent with the power weightings of the specified duty cycle. For example, the average load factor for your recommended cycle (cycle-weighted power divided by rated power) should be equivalent to those of conventional locomotives. We may also allow the use of the standard power levels shown in Table 3 to this section for nonstandard locomotive testing subject to our prior approval. This paragraph (c) does not allow engines to be tested without consideration of the actual notches that will be used.
Percent | |
---|---|
Normal Idle | 0.00 |
Dynamic Brake | 0.00 |
Notch 1 | 4.50 |
Notch 2 | 11.50 |
Notch 3 | 23.50 |
Notch 4 | 35.00 |
Notch 5 | 48.50 |
Notch 6 | 64.00 |
Notch 7 | 85.00 |
Notch 8 | 100.00 |
(d) Optional Ramped Modal Cycle Testing. Tables 1 and 2 of §1033.520 show the weighting factors to use to calculate cycle-weighted average emission rates for the applicable locomotive ramped modal cycle. Use the weighting factors for the ramped modal cycle for your locomotive application and calculate cycle-weighted average emissions as specified in 40 CFR part 1065, subpart G.
(e) Automated Start-Stop. For a locomotive equipped with features that shut the engine off after prolonged periods of idle, multiply the measured idle mass emission rate over the idle portion of the applicable test cycles by a factor equal to one minus the estimated fraction reduction in idling time that will result in use from the shutdown feature. Do not apply this factor to the weighted idle power. Application of this adjustment is subject to our approval if the fraction reduction in idling time that is estimated to result from the shutdown feature is greater than 25 percent. This paragraph (e) does not apply if the locomotive is (or will be) covered by a separate certificate for idle control.
(f) Multi-engine locomotives. This paragraph (f) applies for locomotives using multiple engines where all engines are identical in all material respects. In cases where we allow engine dynamometer testing, you may test a single engine consistent with good engineering judgment, as long as you test it at the operating points at which the engines will operate when installed in the locomotive (excluding stopping and starting). Weigh the results to reflect the power demand/power-sharing of the in-use configuration for each notch setting.
(g) Representative test cycles for freshly manufactured locomotives. As specified in this paragraph (g), manufacturers may be required to use an alternate test cycle for freshly manufactured Tier 3 and later locomotives.
(1) If you determine that you are adding design features that will make the expected average in-use duty cycle for any of your freshly manufactured locomotive engine families significantly different from the otherwise applicable test cycle (including weighting factors), you must notify us and recommend an alternate test cycle that represents the expected average in-use duty cycle. You should also obtain preliminary approval before you begin collecting data to support an alternate test cycle. We will specify whether to use the default duty cycle, your recommended cycle, or a different cycle, depending on which cycle we believe best represents expected in-use operation.
(2) The provisions of this paragraph (g) apply differently for different types of locomotives, as follows:
(i) For Tier 4 and later line-haul locomotives, use the cycle required by (g)(1) of this section to show compliance with the line-haul cycle standards.
(ii) For Tier 3 and later switch locomotives, use the cycle required by (g)(1) of this section to show compliance with the switch cycle standards.
(iii) For Tier 3 line-haul locomotives, if we specify an alternate cycle, use it to show compliance with the line-haul cycle standards. If you include the locomotives in the ABT program of subpart H of this part, calculate line-haul cycle credits (positive or negative) using the alternate cycle and the line-haul cycle standards. Your locomotive is deemed to also generate an equal amount of switch cycle credits.
(3) For all locomotives certified using an alternate cycle, include a description of the cycle in the owners manual such that the locomotive can be remanufactured using the same cycle.
(4) For example, if your freshly manufactured line-haul locomotives are equipped with load control features that modify how the locomotive will operate when it is in a consist, and such features will cause the locomotives to operate differently from the otherwise applicable line-haul cycle, we may require you to certify using an alternate cycle.
(5) See paragraph (h) of this section for cycle-changing design features that also result in energy savings.
(h) Calculation adjustments for energy-saving design features. The provisions of this paragraph (h) apply for locomotives equipped with new energy-saving locomotive design features. They do not apply for features that only improve the engine's brake-specific fuel consumption. They also do not apply for features that were commonly incorporated in locomotives before 2008. See paragraph (h)(6) of this section for provisions related to determining whether certain features are considered to have been commonly incorporated in locomotives before 2008.
(1) Manufacturers/remanufacturers choosing to adjust emissions under this paragraph (h) must do all of the following for certification:
(i) Describe the energy-saving features in your application for certification.
(ii) Describe in your installation instruction and/or maintenance instructions all steps necessary to utilize the energy-saving features.
(2) If your design feature will also affect the locomotives' duty cycle, you must comply with the requirements of paragraph (g) of this section.
(3) Calculate the energy savings as follows:
(i) Estimate the expected mean in-use fuel consumption rate (on a BTU per ton-mile basis) with and without the energy saving design feature, consistent with the specifications of paragraph (h)(4) of this section. The energy savings is the ratio of fuel consumed from a locomotive operating with the new feature to fuel consumed from a locomotive operating without the feature under identical conditions. Include an estimate of the 80 percent confidence interval for your estimate of the mean and other statistical parameters we specify.
(ii) Your estimate must be based on in-use operating data, consistent with good engineering judgment. Where we have previously certified your design feature under this paragraph (h), we may require you to update your analysis based on all new data that are available. You must obtain approval before you begin collecting operational data for this purpose.
(iii) We may allow you to consider the effects of your design feature separately for different route types, regions, or railroads. We may require that you certify these different locomotives in different engine families and may restrict their use to the specified applications.
(iv) Design your test plan so that the operation of the locomotives with and without is as similar as possible in all material aspects (other than the design feature being evaluated). Correct all data for any relevant differences, consistent with good engineering judgment.
(v) Do not include any brake-specific energy savings in your calculated values. If it is not possible to exclude such effects from your data gathering, you must correct for these effects, consistent with good engineering judgment.
(4) Calculate adjustment factors as described in this paragraph (h)(4). If the energy savings will apply broadly, calculate and apply the adjustment on a cycle-weighted basis. Otherwise, calculate and apply the adjustment separately for each notch. To apply the adjustment, multiply the emissions (either cycle-weighted or notch-specific, as applicable) by the adjustment. Use the lower bound of the 80 percent confidence interval of the estimate of the mean as your estimated energy savings rate. We may cap your energy savings rate for this paragraph (h)(4) at 80 percent of the estimate of the mean. Calculate the emission adjustment factors as:
AF = 1.000 − (energy savings rate)
(5) We may require you to collect and report data from locomotives we allow you to certify under this paragraph (h) and to recalculate the adjustment factor for future model years based on such data.
(6) Features that are considered to have not been commonly incorporated in locomotives before 2008 include but are not limited to those identified in this paragraph (h)(6).
(i) Electronically controlled pneumatic (ECP) brakes, computerized throttle management control, and advanced hybrid technology were not commonly incorporated in locomotives before 2008. Manufacturers may claim full credit for energy savings that result from applying these features to freshly manufactured and/or remanufactured locomotives.
(ii) Distributed power systems that use radio controls to optimize operation of locomotives in the middle and rear of a train were commonly incorporated in some but not all locomotives in 2008. Manufacturers may claim credit for incorporating these features into locomotives as follows:
(A) Manufacturers may claim prorated credit for incorporating distributed power systems in freshly manufactured locomotives. Multiply the energy saving rate by 0.50 when calculating the adjustment factor:
AF = 1.000−(energy savings rate) × (0.50)
(B) Manufacturers may claim full credit for retrofitting distributed power systems in remanufactured locomotives.
[73 FR 37197, June 30, 2008, as amended at 73 FR 59190, Oct. 8, 2008; 75 FR 22985, Apr. 30, 2010]
§1033.535 Adjusting emission levels to account for infrequently regenerating aftertreatment devices.
For locomotives using aftertreatment technology with infrequent regeneration events that may occur during testing, take one of the following approaches to account for the emission impact of regeneration:
(a) You may use the calculation methodology described in 40 CFR 1065.680 to adjust measured emission results. Do this by developing an upward adjustment factor and a downward adjustment factor for each pollutant based on measured emission data and observed regeneration frequency as follows:
(1) Adjustment factors should generally apply to an entire engine family, but you may develop separate adjustment factors for different configurations within an engine family. Use the adjustment factors from this section for all testing for the engine family.
(2) You may use carryover or carry-across data to establish adjustment factors for an engine family as described in §1033.235, consistent with good engineering judgment.
(3) Determine the frequency of regeneration, F, as described in 40 CFR 1065.680 from in-use operating data or from running repetitive tests in a laboratory. If the engine is designed for regeneration at fixed time intervals, you may apply good engineering judgment to determine F based on those design parameters.
(4) Identify the value of F in each application for the certification for which it applies.
(5) Apply the provisions for ramped-modal testing based on measurements for each test interval rather than the whole ramped-modal test.
(b) You may ask us to approve an alternate methodology to account for regeneration events. We will generally limit approval to cases where your engines use aftertreatment technology with extremely infrequent regeneration and you are unable to apply the provisions of this section.
(c) You may choose to make no adjustments to measured emission results if you determine that regeneration does not significantly affect emission levels for an engine family (or configuration) or if it is not practical to identify when regeneration occurs. If you choose not to make adjustments under paragraph (a) or (b) of this section, your locomotives must meet emission standards for all testing, without regard to regeneration.
[81 FR 74008, Oct. 25, 2016]