Compliance Just Got Easier: Stay ahead of regulatory changes with instant notifications on updates that matter.
['CERCLA, SARA, EPCRA', 'Tank Systems', 'Oil Spill Prevention']
['Secondary Containment', 'Field Constructed Tanks', 'Release Detection', 'Tank Systems', 'Aboveground Storage Tanks', 'Oil Spill Prevention', 'Contingency Planning', 'Release Notifications', 'Containment Buildings', 'Overfill Prevention', 'Oil Spills']
01/18/2024
Aboveground storage tanks (AST) state comparison
RegSenseContainment BuildingsCERCLA, SARA, EPCRAWaste/HazWasteField Constructed TanksEnvironmental Protection Agency (EPA)Oil Spill PreventionOil Spill PreventionOccupational Safety and Health Administration (OSHA), DOLCWA ComplianceEnglishTank SystemsTank SystemsRelease NotificationsSafety & HealthAboveground Storage TanksContingency PlanningGeneral Industry SafetySecondary ContainmentOverfill PreventionBest ResultsEnvironmentalState Comparison TableOil SpillsFocus AreaRelease DetectionUSA
Each state manages aboveground storage tanks differently. Use the chart below to determine if additional requirements apply to your operations.
Federal regulatory citation
- 40 CFR 112 — Oil Pollution Prevention
- 40 CFR 260 — Hazardous Waste Management System: General
- 40 CFR 262 — Standards Applicable to Generators of Hazardous Waste
- 40 CFR 264 — Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities
- 40 CFR 265 — Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities
- 40 CFR 268 — Land Disposal Restrictions
- 40 CFR 280 — Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks (UST)
- 29 CFR 1910.106 — Flammable Liquids.
State comparison
| State | Adherence to federal regulations | State regulatory citation(s) | State-specific requirements |
|---|---|---|---|
| Alabama | Federal and state | ADEM Administrative Code R. 335-6-15 (primarily UST regulations) | State information |
| Alaska | Federal and state | 18 AAC 75, Article 9 | State information |
| Arizona | Federal and state | Arizona Fire Code | State information |
| Arkansas | Federal and state | Regulation No. 12 | State information |
| California | Federal and state | Chapter 6.67 - Aboveground Petroleum Storage Act | State information |
| Colorado | Federal and state | 7 CCR 1101-14 | State information |
| Connecticut | Federal and state | State information | |
| Delaware | Federal and state | Title 7, 1352 | State information |
| District of Columbia | Federal and state | Fire BOCA codes | State information |
| Florida | Federal and state | Florida Statutes 376.303 - Rule Chapter 62-762 | State information |
| Georgia | Federal and state | CGA 25-2-16 and GRR 120-3-11 | State information |
| Hawaii | Federal and state | HRS 132-1 to 132-19 (Fire protection) and Hawaii State Fire Code | View federal |
| Idaho | Federal and state | IDAPA 58.01.05 | State information |
| Illinois | Federal and state | 41 Ill. Adm. Code 160 Rules for Aboveground BULK Storage Tanks - 41 Ill. Adm. Code 180 Rules for Aboveground FUEL DISPENSING Storage Tanks | State information |
| Indiana | Federal and state | 327 IAC 2-10 | View federal |
| Iowa | Federal and state | IAC 661-224.1(101) to IAC 224.8(101) | State information |
| Kansas | Federal and state | K.A.R. 28-44: Petroleum Products Storage Tanks -Kansas Storage Tank Act 65-34 | State information |
| Kentucky | Federal and state | KY Fire Prevention Code, 815 KAR 7:120 and 815 KAR 10:060 | State information |
| Louisiana | Federal and state | Adopted NFPA 30, 30A, and 70 Fire Marshal’s Office | View federal |
| Maine | Federal and state | 570-K - Aboveground oil storage facilities | State information |
| Maryland | Federal and state | COMAR 26.10.01.12 | State information |
| Massachusetts | Federal and state | 502 CMR 5.00 - MGL Ch. 148 S. 37 | State information |
| Michigan | Federal and state | R 29.5601 to .5917 | State information |
| Minnesota | Federal and state | MAR Chapter 7151 | State information |
| Mississippi | Federal and state | MS Code Ann. 45-11-101 - 111 and MS Code Ann. 45-11-3 | State information |
| Missouri | Federal and state | 2 CSR 90-30.050 and .070 | State information |
| Montana | Federal and state | Administrative Rules of Montana (ARM) 23.12.601 | State information |
| Nebraska | Federal and state | Title 158 | State information |
| Nevada | Federal and state | Nevada Administrative Code 459.9931 | State information |
| New Hampshire | Federal and state | Env-Or 300 | State information |
| New Jersey | Federal and state | Building Officials and Code Administrators (BOCA), New Jersey Administrative Code 5:23-3.14 and NJAC 5:23-3.20. | State information |
| New Mexico | Federal and state | NMAC 20.5.109; 20.5.110; 20.5.111; 20.5.112 | State information |
| New York | Federal and state | Subpart 613-4 | State information |
| North Carolina | Federal and state | North Carolina Building Code, Chapter 22 of the North Carolina Fire Code and the National Fire Protection Association Standard 30 and 30A (NFPA 30 and NFPA 30A). | State information |
| North Dakota | Federal and state | National Fire Protection Standards 30 and 30A - North Dakota Administrative Code Chapter 10-07. | State information |
| Ohio | Federal and state | Chapter 1301:7-7 - Section 603.3.2 | State information |
| Oklahoma | Federal and state | OAC 165:26-1 to 165:26-16 and Appendices G to J | State information |
| Oregon | Federal and state | OAR 837-040-0010 | State information |
| Pennsylvania | Federal and state | 34 Pa. Code. Chapters 14 and 14a | State information |
| Rhode Island | Federal and state | 250 RICR 140-25-2 | State information |
| South Carolina | Federal and state | S.C. Code Ann 48-1-10 to 48-1-350 | State information |
| South Dakota | Federal and state | 34A-2-100 - 34A-2-101 - Chapter 74:56:03 | State information |
| Tennessee | Federal and state | Adopted NFPA 30, 30A, and 70 | State information |
| Texas | Federal and state | 30 TAC 334, Subchapter F | State information |
| Utah | Federal and state | UCA 15A-1-403 | State information |
| Vermont | Federal and state | Aboveground Storage Tank Rules, 9-101 through -308 and VSA 20, 2799 to 2802 | State information |
| Virginia | Federal and state | Title 9, Agency 25, Chapter 91 and VA Code 62.1-44.34:15.1 | State information |
| Washington | Federal and state | RCW 19.27 | State information |
| West Virginia | Federal and state | W. Va Code 22-30 - 47 CSR 62, 64, and 65 | State information |
| Wisconsin | Federal and state | WI DATCP 93.010 to 93.880 | State information |
| Wyoming | Federal and state | WS 35-11-1414 to 35-11-1430 and WCWR 020-0014-1 (Environmental Quality (020)/Storage Tanks (0014) | State information |
['CERCLA, SARA, EPCRA', 'Tank Systems', 'Oil Spill Prevention']
['Secondary Containment', 'Field Constructed Tanks', 'Release Detection', 'Tank Systems', 'Aboveground Storage Tanks', 'Oil Spill Prevention', 'Contingency Planning', 'Release Notifications', 'Containment Buildings', 'Overfill Prevention', 'Oil Spills']
UPGRADE TO CONTINUE READING
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2026 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.