['Air Programs']
['Air Quality', 'Acid Rain']
07/31/2023
...
§75.40 General demonstration requirements.
(a) The owner or operator of an affected unit, or the owner or operator of an affected unit and representing a class of affected units which meet the criteria specified in §75.47, required to install a continuous emission monitoring system may apply to the Administrator for approval of an alternative monitoring system (or system component) to determine average hourly emission data for SO2, NOX, and/or volumetric flow by demonstrating that the alternative monitoring system has the same or better precision, reliability, accessibility, and timeliness as that provided by the continuous emission monitoring system.
(b) The requirements of this subpart shall be met by the alternative monitoring system when compared to a contemporaneously operating, fully certified continuous emission monitoring system or a contemporaneously operating reference method, where the appropriate reference methods are listed in §75.22.
§75.41 Precision criteria.
(a) Data collection and analysis. To demonstrate precision equal to or better than the continuous emission monitoring system, the owner or operator shall conduct an F-test, a correlation analysis, and a t-test for bias as described in this section. The t-test shall be performed only on sample data at the normal operating level and primary fuel supply, whereas the F-test and the correlation analysis must be performed on each of the data sets required under paragraphs (a)(4) and (a)(5) of this section. The owner or operator shall collect and analyze data according to the following requirements:
(1) Data from the alternative monitoring system and the continuous emission monitoring system shall be collected and paired in a manner that ensures each pair of values applies to hourly average emissions during the same hour.
(2) An alternative monitoring system that directly measures emissions shall have probes or other measuring devices in locations that are in proximity to the continuous emission monitoring system and shall provide data on the same parameters as those measured by the continuous emission monitoring system. Data from the alternative monitoring system shall meet the statistical tests for precision in paragraph (c) of this section and the t-test for bias in appendix A of this part.
(3) An alternative monitoring system that indirectly quantifies emission values by measuring inputs, operating characteristics, or outputs and then applying a regression or another quantitative technique to estimate emissions, shall meet the statistical tests for precision in paragraph (c) of this section and the t-test for bias in appendix A of this part.
(4) For flow monitor alternatives, the alternative monitoring system must provide sample data for each of three different exhaust gas velocities while the unit or units, if more than one unit exhausts into the stack or duct, is burning its primary fuel at:
(i) A frequently used low operating level, selected within the range between the minimum safe and stable operating level and 50 percent of the maximum operating level,
(ii) A frequently used high operating level, selected within the range between 80 percent of the maximum operating level and the maximum operating level, and
(iii) The normal operating level, or an evenly spaced intermediary level between low and high levels used if the normal operating level is within a specified range (10.0 percent of the maximum operating level), of either paragraphs (a)(4) (i) or (ii) of this section.
(5) For pollutant concentration monitor alternatives, the alternative monitoring system shall provide sample data for the primary fuel supply and for all alternative fuel supplies that have significantly different sulfur content.
(6) For the normal unit operating level and primary fuel supply, paired hourly sample data shall be provided for at least 90.0 percent of the hours during 720 unit operating hours. For each of the remaining two operating levels for flow monitor alternatives, and for each alternative fuel supply for pollutant concentration monitor alternatives, paired hourly sample data shall be provided for at least 24 successive unit operating hours.
(7) The owner or operator shall not use missing data substitution procedures to provide sample data.
(8) If the collected data meet the requirements of the F-test, the correlation test, and the t-test at one or more, but not all, of the operating levels or fuel supplies, the owner or operator may elect to continue collecting the paired data for up to 1,440 additional operating hours and repeat the statistical tests using the data for the entire 30- to 90-day period.
(9) The owner or operator shall provide two separate time series data plots for the data at each operating level or fuel supply described in paragraphs (a)(4) and (a)(5) of this section. Each data plot shall have a horizontal axis that represents the clock hour and calendar date of the readings and shall contain a separate data point for every hour for the duration of the performance evaluation. The data plots shall show the following:
(i) Percentage difference versus time where the vertical axis represents the percentage difference between each paired hourly reading generated by the continuous emission monitoring system (or reference method) and the alternative emission monitoring system as calculated using the following equation:
(Eq. 10)
where,
? e = Percentage difference between the readings generated by the alternative monitoring system and the continuous emission monitoring system.
ep = Measured value from the alternative monitoring system.
ev = Measured value from the continuous emission monitoring system.
(ii) Alternative monitoring system readings and continuous emission monitoring system (or reference method) readings versus time where the vertical axis represents hourly pollutant concentrations or volumetric flow, as appropriate, and two different symbols are used to represent the readings from the alternative monitoring system and the continuous emission monitoring system (or reference method), respectively.
(b) Data screening and calculation adjustments. In preparation for conducting the statistical tests described in paragraph (c) of this section, the owner or operator may screen the data for lognormality and time dependency autocorrelation. If either is detected, the owner or operator shall make the following calculation adjustments:
(1) Lognormality. The owner or operator shall conduct any screening and adjustment for lognormality according to the following procedures.
(i) Apply the log transformation to each measured value of either the certified continuous emissions monitoring system or certified flow monitor, using the following equation:
lv = ln ev
(Eq. 11)
where,
ev = Hourly value generated by the certified continuous emissions monitoring system or certified flow monitoring system
lv = Hourly lognormalized data values for the certified monitoring system
and to each measured value, ep, of the proposed alternative monitoring system, using the following equation to obtain the lognormalized data values, lp:
lp = ln ep
(Eq. 12)
where,
ep = Hourly value generated by the proposed alternative monitoring system.
lp = Hourly lognormalized data values for the proposed alternative monitoring system.
(ii) Separately test each set of transformed data, lv and lp, for normality, using the following:
(A) Shapiro-Wilk test;
(B) Histogram of the transformed data; and
(C) Quantile-Quantile plot of the transformed data.
(iii) The transformed data in a data set will be considered normally distributed if all of the following conditions are satisfied:
(A) The Shapiro-Wilk test statistic, W, is greater than or equal to 0.75 or is not statistically significant at ? = 0.05.
(B) The histogram of the data is unimodal and symmetric.
(C) The Quantile-Quantile plot is a diagonal straight line.
(iv) If both of the transformed data sets, lv and lp, meet the conditions for normality, specified in paragraphs (b)(1)(iii) (A) through (C) of this section, the owner or operator may use the transformed data, lv and lp, in place of the original measured data values in the statistical tests for alternative monitoring systems as described in paragraph (c) of this section and in appendix A of this part.
(v) If the transformed data are used in the statistical tests in paragraph (c) of this section and in appendix A of this part, the owner or operator shall provide the following:
(A) Copy of the original measured values and the corresponding transformed data in printed and electronic format.
(B) Printed copy of the test results and plots described in paragraphs (b)(1) (i) through (iii) of this section.
(2) Time dependency (autocorrelation). The screening and adjustment for time dependency are conducted according to the following procedures:
(i) Calculate the degree of autocorrelation of the data on their LAG1 values, where the degree of autocorrelation is represented by the Pearson autocorrelation coefficient, ?, computed from an AR(1) autoregression model, such that:
(Eq. 13)
where,
x?i = The original data value at hour i.
x?i = The LAG1 data value at hour i.
COV(x?i, x?i) = The autocovariance of x?i and defined by,
(Eq. 14)
where,
n = The total number of observations in which both the original value, x?i, and the lagged value, x?i, are available in the data set.
s?x i = The standard deviation of the original data values, x?i defined by,
(Eq. 15)
where,
s?x i = The standard deviation of the LAG1 data values, x?i, defined by
(Eq. 16)
where,
x? = The mean of the original data values, x?i defined by
(Eq. 17)
where,
x? = The mean of the LAG1 data values, x?i, defined by
(Eq. 18)
where,
(ii) The data in a data set will be considered autocorrelated if the autocorrelation coefficient, ?, is significant at the 5 percent significance level. To determine if this condition is satisfied, calculate Z using the following equation:
(Eq. 19)
If Z >1.96, then the autocorrelation coefficient, ?, is significant at the 5 percent significance level (a = 0.05).
(iii) If the data in a data set satisfy the conditions for autocorrelation, specified in paragraph (b)(2)(ii) of this section, the variance of the data, S2, may be adjusted using the following equation:
S2adj = VIF × S2
(Eq. 20)
where,
S2 = The original, unadjusted variance of the data set.
VIF = The variance inflation factor, defined by
(Eq. 21)
S2adj = The autocorrelation-adjusted variance for the data set.
(iv) The procedures described in paragraphs (b)(2)(i)-(iii) of this section may be separately applied to the following data sets in order to derive distinct autocorrelation coefficients and variance inflation factors for each data set:
(A) The set of measured hourly values, ev, generated by the certified continuous emissions monitoring system or certified flow monitoring system.
(B) The set of hourly values, ep, generated by the proposed alternative monitoring system,
(C) The set of hourly differences, ev-ep, between the hourly values, ev, generated by the certified continuous emissions monitoring system or certified flow monitoring system and the hourly values, ep, generated by the proposed alternative monitoring system.
(v) For any data set, listed in paragraph (b)(2)(iv) of this section, that satisfies the conditions for autocorrelation specified in paragraph (b)(2)(ii) of this section, the owner or operator may adjust the variance of that data set, using equation 20 of this section.
(A) The adjusted variance may be used in place of the corresponding original variance, as calculated using equation 23 of this section, in the F-test (Equation 24) of this section.
(B) In place of the standard error of the mean,
in the bias test Equation A-9 of appendix A of this part the following adjusted standard error of the mean may be used:
(Eq. 22)where
(vi) For each data set in which a variance adjustment is used, the owner or operator shall provide the following:
(A) All values in the data set in printed and electronic format.
(B) Values of the autocorrelation coefficient, its level of significance, the variance inflation factor, and the unadjusted original and adjusted values found in equations 20 and 22 of this section.
(C) Equation and related statistics of the AR(1) autoregression model of the data set.
(D) Printed documentation of the intermediate calculations used to derive the autocorrelation coefficient and the Variance Inflation Factor.
(c) Statistical Tests. The owner or operator shall perform the F-test and correlation analysis as described in this paragraph and the t-test for bias described in appendix A of this part to demonstrate the precision of the alternative monitoring system.
(1) F-test. The owner or operator shall conduct the F-test according to the following procedures.
(i) Calculate the variance of the certified continuous emission monitoring system or certified flow monitor as applicable, Sv2, and the proposed method, Sp2, using the following equation.
(Eq. 23)
where,
ei = Measured values of either the certified continuous emission monitoring system or certified flow monitor, as applicable, or proposed method.
em = Mean of either the certified continuous emission monitoring system or certified flow monitor, as applicable, or proposed method values.
n = Total number of paired samples.
(ii) Determine if the variance of the proposed method is significantly different from that of the certified continuous emission monitoring system or certified flow monitor, as applicable, by calculating the F-value using the following equation.
(Eq. 24)
Compare the experimental F-value with the critical value of F at the 95-percent confidence level with n-1 degrees of freedom. The critical value is obtained from a table for F-distribution. If the calculated F-value is greater than the critical value, the proposed method is unacceptable.
(2) Correlation analysis. The owner or operator shall conduct the correlation analysis according to the following procedures.
(i) Plot each of the paired emissions readings as a separate point on a graph where the vertical axis represents the value (pollutant concentration or volumetric flow, as appropriate) generated by the alternative monitoring system and the horizontal axis represents the value (pollutant concentration or volumetric flow, as appropriate) generated by the continuous emission monitoring system (or reference method). On the graph, draw a horizontal line representing the mean value, ep, for the alternative monitoring system and a vertical line representing the mean value, ev, for the continuous emission monitoring system where,
(Eq. 25)
(Eq. 26)
where,
ep = Hourly value generated by the alternative monitoring system.
ev = Hourly value generated by the continuous emission monitoring system.
n = Total number of hours for which data were generated for the tests.
A separate graph shall be produced for the data generated at each of the operating levels or fuel supplies described in paragraphs (a)(4) and (a)(5) of this section.
(ii) Use the following equation to calculate the coefficient of correlation, r, between the emissions data from the alternative monitoring system and the continuous emission monitoring system using all hourly data for which paired values were available from both monitoring systems.
(Eq. 27)
(iii) If the calculated r-value is less than 0.8, the proposed method is unacceptable.
[58 FR 3701, Jan. 11, 1993, as amended at 60 FR 26530, May 17, 1995; 60 FR 40296, Aug. 8, 1995; 67 FR 40440, June 12, 2002]
§75.42 Reliability criteria.
To demonstrate reliability equal to or better than the continuous emission monitoring system, the owner or operator shall demonstrate that the alternative monitoring system is capable of providing valid 1-hr averages for 95.0 percent or more of unit operating hours over a 1-yr period and that the system meets the applicable requirements of appendix B of this part.
§75.43 Accessibility criteria.
To demonstrate accessibility equal to or better than the continuous emission monitoring system, the owner or operator shall provide reports and onsite records of emission data to demonstrate that the alternative monitoring system provides data meeting the requirements of subparts F and G of this part.
§75.44 Timeliness criteria.
To demonstrate timeliness equal to or better than the continuous emission monitoring system, the owner or operator shall demonstrate that the alternative monitoring system can meet the requirements of subparts F and G of this part; can provide a continuous, quality-assured, permanent record of certified emissions data on an hourly basis; and can issue a record of data for the previous day within 24 hours.
§75.45 Daily quality assurance criteria.
The owner or operator shall either demonstrate that daily tests equivalent to those specified in appendix B of this part can be performed on the alternative monitoring system or demonstrate and document that such tests are unnecessary for providing quality-assured data.
§75.46 Missing data substitution criteria.
The owner or operator shall demonstrate that all missing data can be accounted for in a manner consistent with the applicable missing data procedures in subpart D of this part.
§75.47 Criteria for a class of affected units.
(a) The owner or operator of an affected unit may represent a class of affected units for the purpose of applying to the Administrator for a class-approved alternative monitoring system.
(b) The owner or operator of an affected unit representing a class of affected units shall provide the following information:
(1) A description of the affected unit and how it appropriately represents the class of affected units;
(2) A description of the class of affected units, including data describing all of the affected units that will comprise the class.
[60 FR 40297, Aug. 8, 1995, as amended at 76 FR 17312, Mar. 28, 2011]
§75.48 Petition for an alternative monitoring system.
(a) The designated representative shall submit the following information in the application for certification or recertification of an alternative monitoring system.
(1) Source identification information.
(2) A description of the alternative monitoring system.
(3) Data, calculations, and results of the statistical tests, specified in §75.41(c) of this part, including:
(i) Date and hour.
(ii) Hourly test data for the alternative monitoring system at each required operating level and fuel type. The fuel type, operating level and gross unit load shall be recorded.
(iii) Hourly test data for the continuous emissions monitoring system at each required operating level and fuel type. The fuel type, operating level and gross unit load shall be recorded.
(iv) Arithmetic mean of the alternative monitoring system measurement values, as specified in Equation 25 in §75.41(c) of this part, of the continuous emission monitoring system values, as specified in Equation 26 in §75.41(c) of this part, and of their differences.
(v) Standard deviation of the difference, as specified in equation A-8 in appendix A of this part.
(vi) Confidence coefficient, as specified in equation A-9 in appendix A of this part.
(vii) The bias test results as specified in §7.6.4 in appendix A of this part.
(viii) Variance of the measured values for the alternative monitoring system and of the measured values for the continuous emission monitoring system, as specified in Equation 23 in §75.41(c) of this part.
(ix) F-statistic, as specified in Equation 24 in §75.41(c) of this part.
(x) Critical value of F at the 95-percent confidence level with n-1 degrees of freedom.
(xi) Coefficient of correlation, r, as specified in Equation 27 in §75.41(c) of this part.
(4) Data plots, specified in §§75.41(a)(9) and 75.41(c)(2)(i) of this part.
(5) Results of monitor reliability analysis.
(6) Results of monitor accessibility analysis.
(7) Results of monitor timeliness analysis.
(8) A detailed description of the process used to collect data, including location and method of ensuring an accurate assessment of operating hourly conditions on a real-time basis.
(9) A detailed description of the operation, maintenance, and quality assurance procedures for the alternative monitoring system as required in appendix B of this part.
(10) A description of methods used to calculate heat input or diluent gas concentration, if applicable.
(11) Results of tests and measurements (including the results of all reference method field test sheets, charts, laboratory analyses, example calculations, or other data as appropriate) necessary to substantiate that the alternative monitoring system is equivalent in performance to an appropriate, certified operating continuous emission monitoring system.
(b) [Reserved]
[60 FR 40297, Aug. 8, 1995, as amended at 64 FR 28605, May 26, 1999]
READ MORESHOW LESS
['Air Programs']
['Air Quality', 'Acid Rain']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2024 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.