(a) Storage vessel requirements. The owner or operator expressly referenced to this subpart from subpart C of this part shall comply with the following requirements, as applicable:
(1) Closed vent system and flare. Owners or operators subject to §65.42(b)(4) who route storage vessel emissions through a closed vent system to a flare shall meet the requirements in §65.143 for closed vent systems; §65.147 for flares; and §65.157(a), (b), and (c) for provisions regarding flare compliance determinations; and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to storage vessel emissions routed through a closed vent system to a flare.
(2) Closed vent system and nonflare control device. Owners or operators subject to §65.42(b)(5) who route storage vessel emissions through a closed vent system to a nonflare control device shall meet the requirements in §65.143 for closed vent systems and §65.145 for nonflare control devices and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to storage vessel emissions routed through a closed vent system to a nonflare control device unless specifically required in the monitoring plan submitted under §65.145(c).
(3) Route to a fuel gas system or process. Owners or operators subject to §65.42(b)(6) who route storage vessel emissions to a fuel gas system or to a process shall meet the requirements in §65.144 and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to storage vessel emissions being routed to a fuel gas system or to a process.
(b) Process vent requirements. The owner or operator expressly referenced to this subpart from subpart D of this part or 40 CFR part 60, subpart DDD, shall comply with the following requirements, as applicable:
(1) Flare. Owners or operators subject to §65.63(a)(1) or 40 CFR 60.562-1(a)(1)(i)(C) who route process vent emissions to a flare shall meet the applicable requirements in §65.143 for closed vent systems; §65.147 for flares; and §65.157(a), (b), and (c) for provisions regarding flare compliance determinations; and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to process vent emissions routed through a closed vent system to a flare.
(2) Nonflare control device. Owners or operators subject to §65.63(a)(2) or 40 CFR 60.562-1(a)(1)(i)(A) or (B) who route process vent emissions to a nonflare control device shall meet the applicable requirements in §65.143 for closed vent systems; the requirements applicable to the control devices being used in §§65.148 through 65.152 or §65.155 the applicable general monitoring requirements of §65.156 the applicable performance test requirements and procedures of §§65.157 and 65.158; and the monitoring, recordkeeping, and reporting requirements referenced therein. Owners or operators subject to the halogen reduction device requirements of §65.63(b)(1) must also comply with §65.154 and the monitoring, recordkeeping, and reporting requirements referenced therein. The requirements of §§65.144 through 65.146 do not apply to process vents. No other provisions of this subpart apply to process vent emissions routed through a closed vent system to a nonflare control device.
(3) Final recovery devices. Owners or operators subject to §65.63(a)(3) who use a final recovery device to maintain the TRE index value of a Group 2A process vent above 1.0 shall meet the requirements in §65.153, and the monitoring, recordkeeping, and reporting requirements referenced therein applicable to the recovery device being used and the applicable monitoring requirements in §65.156, and the recordkeeping and reporting requirements referenced therein, except for §65.156(c)(2)(ii). No other provisions of this subpart apply to Group 2A process vents.
(c) Transfer rack requirements. The owner or operator expressly referenced to this subpart from subpart E of this part shall comply with the following requirements, as applicable:
(1) Closed vent system and flare. Owners or operators subject to §65.83(a)(2) who route transfer rack emissions through a closed vent system to a flare shall meet the applicable requirements in §65.143 for closed vent systems; §65.147 for flares; and §65.157(a), (b), and (c) for provisions regarding flare compliance determinations; and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to transfer rack emissions routed through a closed vent system to a flare.
(2) Closed vent system and nonflare control device for low-throughput transfer racks. Owners or operators of low-throughput transfer racks subject to §65.83(a)(1) who route low-throughput transfer rack emissions through a closed vent system to a nonflare control device shall meet the applicable requirements in §65.143 for closed vent systems and §65.145 for nonflare control devices and the monitoring, recordkeeping, and reporting requirements referenced therein. Owners or operators subject to the halogen reduction requirements of §65.83(b)(1) must also comply with the recordkeeping requirement of §65.160(d) and the reporting requirement of §65.165(d). No other provisions of this subpart apply to low-throughput transfer rack emissions routed through a closed vent system to a nonflare control device unless specifically required in the monitoring plan submitted under §65.145(c).
(3) Closed vent system and nonflare control devices for high-throughput transfer racks. Owners or operators of high-throughput transfer racks subject to §65.83(a)(1) who route high-throughput transfer rack emissions through a closed vent system to a nonflare control device shall meet the applicable requirements in §65.143 for closed vent systems; the requirements applicable to the control device being used in §§65.148 through 65.152 or §65.155 the applicable general monitoring of §65.156 the applicable performance test requirements and procedures of §§65.157 and 65.158; and the monitoring, recordkeeping, and reporting requirements referenced therein. Owners or operators subject to the halogen reduction device requirements of §65.83(b)(1) must also comply with §65.154 and the monitoring, recordkeeping, and reporting requirements referenced therein. The requirements of §§65.144 through 65.146 do not apply to high-throughput transfer rack emissions routed through a closed vent system to a nonflare control device. No other provisions of this subpart apply to high-throughput transfer rack emissions routed through a closed vent system to a nonflare control device.
(4) Route to a fuel gas system or to a process. Owners or operators subject to §65.83(a)(4) of this part who route transfer rack emissions to a fuel gas system or to a process shall meet the applicable requirements in §65.144 and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to transfer rack emissions being routed to a fuel gas system or to a process.
(d) Equipment leak requirements. The owner or operator expressly referenced to this subpart from subpart F of this part shall comply with the following requirements, as applicable:
(1) Closed vent system and flare. Owners or operators subject to §65.115(b) who route equipment leak emissions through a closed vent system to a flare shall meet the requirements in §65.143 for closed vent systems; §65.147 for flares; and §65.157(a), (b), and (c) for provisions regarding flare compliance determinations; and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to equipment leak emissions routed through a closed vent system to a flare.
(2) Closed vent system and nonflare control device. Owners or operators subject to §65.115(b) who route equipment leak emissions through a closed vent system to a nonflare control device shall meet the requirements in §65.143 for closed vent systems, §65.146 for nonflare control devices used for equipment leak emissions, and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to equipment leak emissions routed through a closed vent system to a nonflare control device.
(3) Route to a fuel gas system or to a process. Owners or operators subject to §65.115(b) who route equipment leak emissions to a fuel gas system or to a process shall meet the requirements in §65.144 and the monitoring, recordkeeping, and reporting requirements referenced therein. No other provisions of this subpart apply to equipment leak emissions being routed to a fuel gas system or to a process.
(e) Combined emissions. When emissions of different kinds (for example, emissions from process vents, transfer racks, and/or storage vessels) are combined, the owner or operator shall comply with the requirements of either paragraph (e)(1) or (2) of this section:
(1) Comply with the applicable requirements of this subpart for each kind of emissions in the stream (for example, the requirements of §65.142(b) for process vents, and the requirements of §65.142(c) for transfer racks); or
(2) Comply with the first set of requirements identified in paragraphs (e)(2)(i) through (iii) of this section which applies to any individual emission stream that is included in the combined stream. Compliance with the first applicable set of requirements identified in paragraphs (e)(2)(i) through (iii) of this section constitutes compliance with all other requirements in paragraphs (e)(2)(i) through (iii) of this section applicable to other types of emissions in the combined stream. The hierarchy is as follows:
(i) The requirements of §65.142(b) for Group 1 process vents, including applicable monitoring, recordkeeping, and reporting;
(ii) The requirements of §65.142(c) for high-throughput transfer racks, including applicable monitoring, recordkeeping, and reporting;
(iii) The requirements of §65.142(a) for control of emissions from storage vessels or low-throughput transfer racks, including monitoring, recordkeeping, and reporting.