['Air Programs']
['Greenhouse Gases']
05/22/2023
...
Natural gas distribution | Emission Factor (scf/hour/component) |
Leaker Emission Factors—Transmission-Distribution Transfer Station1 Components, Gas Service | |
Connector | 1.69 |
Block Valve | 0.557 |
Control Valve | 9.34 |
Pressure Relief Valve | 0.27 |
Orifice Meter | 0.212 |
Regulator | 0.772 |
Open-ended Line | 26.131 |
Population Emission Factors—Below Grade Metering-Regulating station1 Components, Gas Service2 | |
Below Grade M&R Station, Inlet Pressure >300 psig | 1.30 |
Below Grade M&R Station, Inlet Pressure 100 to 300 psig | 0.20 |
Below Grade M&R Station, Inlet Pressure < 100 psig | 0.10 |
Population Emission Factors—Distribution Mains, Gas Service3 | |
Unprotected Steel | 12.58 |
Protected Steel | 0.35 |
Plastic | 1.13 |
Cast Iron | 27.25 |
Population Emission Factors—Distribution Services, Gas Service4 | |
Unprotected Steel | 0.19 |
Protected Steel | 0.02 |
Plastic | 0.001 |
Copper | 0.03 |
2 Emission Factor is in units of “scf/hour/station.”
3 Emission Factor is in units of “scf/hour/mile.”
4 Emission Factor is in units of “scf/hour/number of services.”
[75 FR 74514, Nov. 30, 2010; 76 FR 80594, Dec. 23, 2011]
['Air Programs']
['Greenhouse Gases']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.