Onshore natural gas processing | Emission Factor (scf/hour/component) |
Leaker Emission Factors—Compressor Components, Gas Service | |
Valve1 | 14.84 |
Connector | 5.59 |
Open-Ended Line | 17.27 |
Pressure Relief Valve | 39.66 |
Meter | 19.33 |
Leaker Emission Factors—Non-Compressor Components, Gas Service | |
Valve | 6.42 |
Connector | 5.71 |
Open-Ended Line | 11.27 |
Pressure Relief Valve | 2.01 |
Meter | 2.93 |
[75 FR 74514 Nov. 30, 2010; 76 FR 80592, Dec. 23, 2011]
['Air Programs']
['Greenhouse Gases']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.