Deck fitting type | Deck fitting loss factor (KF) a | Typical number of fittings (NF) |
---|---|---|
a Units for KF are pound-moles per year.
b If no specific information is available, this value can be assumed to represent the most common/typical deck fittings currently used. c D = Tank diameter (feet). d Not used on welded contact internal floating decks. | ||
Access hatch | 1. | |
Bolted cover, gasketed | 1.6 | |
Unbolted cover, gasketed | 11 | |
Unbolted cover, ungasketed | b 25 | |
Automatic gauge float well | 1. | |
Bolted cover, gasketed | 5.1 | |
Unbolted cover, gasketed | 15 | |
Unbolted cover, ungasketed | b 28 | |
Column well | (see Table 24). | |
Builtup column-sliding cover, gasketed | 33 | |
Builtup column-sliding cover, ungasketed | b 47
10 | |
Pipe column-flexible fabric sleeve seal | 19 | |
Pipe column-sliding cover, gasketed | 32 | |
Pipe column-sliding cover, ungasketed | ||
Ladder well | 1. | |
Sliding cover, gasketed | 56 | |
Sliding cover, ungasketed | b 76 | |
Roof leg or hanger well | (5 + D/10 + D 2/600) c. | |
Adjustable | b 7.9 | |
Fixed | 0 | |
Sample pipe or well | 1. | |
Slotted pipe-sliding cover, gasketed | 44 | |
Slotted pipe-sliding cover, ungasketed | 57 | |
Sample well-slit fabric seal, 10 percent open area | b 12 | |
Stub drain, 1-in diameter d | 1.2 | (D 2/125) c. |
Vacuum breaker | 1. | |
Weighted mechanical actuation, gasketed | b 0.7 | |
Weighted mechanical actuation, ungasketed | 0.9 |
['Air Programs']
['Hazardous Air Pollutants']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.