['Air Programs']
['Hazardous Air Pollutants']
02/23/2023
...
Table 1 to Subpart PPPPPP of Part 63 - Emission Limits
[Change Notice] [Previous Text]
As stated in §63.11423(a)(2), you must comply with the emission limits in the following table:
For . . . | You must . . . |
---|---|
1. Each new or existing grid casting facility | Emit no more than 0.08 milligram of lead per dry standard cubic meter of exhaust (0.000035 gr/dscf). |
2. Each new or existing paste mixing facility | Emit no more than 0.1 milligram of lead per dry standard cubic meter of exhaust (0.0000437 gr/dscf); or emit no more than 0.9 gram of lead per hour (0.002 lbs/hr) total from all paste mixing operations. |
3. Each new or existing three-process operation facility | Emit no more than 1.0 milligram of lead per dry standard cubic meter of exhaust (0.000437 gr/dscf). |
4. Each new or existing lead oxide manufacturing facility | Emit no more than 5.0 milligram of lead per kilogram of lead feed (0.010 lb/ton). |
5. Each new or existing lead reclamation facility | Emit no more than 0.45 milligram of lead per dry standard cubic meter of exhaust (0.000197 gr/dscf). |
6. Each new or existing other lead-emitting operation | Emit no more than 1.0 milligram of lead per dry standard cubic meter of exhaust (0.000437 gr/dscf). |
[72 FR 38913, July 16, 2007, as amended at 73 FR 15929, Mar. 26, 2008; 88 FR 11596, Feb. 23, 2023]
Table 2 to Subpart PPPPPP of Part 63—Opacity Standards
As stated in §63.11423(a)(2), you must comply with the opacity standards in the following table:
As stated in §63.11423(a)(2), you must comply with the opacity standards in the following table:
[88 FR 11596, Feb. 23, 2023]
Table 3 to Subpart PPPPPP of Part 63—Applicability of General Provisions to This Subpart
As required in §63.11425, you must comply with the requirements of the NESHAP General Provisions (subpart A of this part) as shown in the following table.
Citation | Subject | Applies to this subpart? | Explanation |
---|---|---|---|
63.1 | Applicability | Yes | |
63.2 | Definitions | Yes | |
63.3 | Units and Abbreviations | ||
63.4 | Prohibited Activities and Circumvention | Yes | |
63.5 | Preconstruction Review and Notification Requirements | No | |
63.6(a) through (d) | Compliance with Standards and Maintenance Requirements | Yes | |
63.6(e)(1)(i) | General Duty to Minimize Emissions | No | Section 63.11423(a)(3) specifies general duty requirements. |
63.6(e)(1)(ii) | Requirement to correct malfunctions as soon as possible | No | |
63.6(e)(1)(iii) | Enforceability of requirements independent of other regulations | Yes | |
63.6(e)(3) | SSM Plans | No | This subpart does not require a startup, shutdown, and malfunction plan. |
63.6(f)(1) | Compliance Except During SSM | No | |
63.6(f)(2) and (3) | Methods for determining compliance | Yes | |
63.6(g) | Use of an alternative nonopacity emission standard | Yes | |
63.6(h)(1) | SSM Exemption | No | |
63.6(h)(2) through (9), (i) through (j) | Compliance with opacity/visible emission standards, compliance extensions and exemptions | Yes | |
63.7(a) through (d), (e)(2) and (3), (f) through (h) | Performance Testing Requirements | Yes | |
63.7(e)(1) | Conditions for conducting performance tests | No | Requirements for performance test conditions are found in §63.11423(c)(7). |
63.8(a), (b), (c)(1)(ii), (d)(1) and (2), (e) through (g) | Monitoring Requirements | Yes | |
63.8(c)(1)(i) | General duty to minimize emissions and CMS operation | No | Section 63.11423(a)(3) specifies general duty requirements. |
63.8(c)(1)(iii) | Requirement to develop SSM Plan for CMS | No | |
63.8(d)(3) | Written procedures for CMS | No | |
63.9 | Notification Requirements | Yes | |
63.10(a), (b)(1), (b)(2)(iii), (b)(2)(vi) through (ix), (b)(3), (c)(1) through (14), (d)(1) through (4), (e), (f) | Recordkeeping and Reporting Requirements | Yes | |
63.10(b)(2)(i) | Recordkeeping of occurrence and duration of startups and shutdowns | No | |
63.10(b)(2)(ii) | Recordkeeping of failures to meet a standard | No | Section 63.11424(a)(5) specifies these requirements. |
63.10(b)(2)(iv) and (v) | Actions taken to minimize emissions during SSM | No | |
63.10(c)(15) | Use of SSM Plan | No | |
63.10(d)(5) | No | This subpart does not require a startup, shutdown, and malfunction plan. See §63.11424(c) for excess emissions reporting requirements. | |
63.11 | Control Device Requirements | No | This subpart does not require flares. |
63.12 | State Authorities and Delegations | Yes | |
63.13 | Addresses | Yes | |
63.14 | Incorporations by Reference | Yes | |
63.15 | Availability of Information and Confidentiality | Yes | |
63.16 | Performance Track Provisions | Yes | |
63.1(a)(5), (a)(7) through (9), (b)(2), (c)(3), (d), 63.6(b)(6), (c)(3) and (4), (d), (e)(2), (e)(3)(ii), (h)(3), (h)(5)(iv), 63.8(a)(3), 63.9(b)(3), (h)(4), 63.10(c)(2) through (4), (c)(9) | Reserved | No |
[88 FR 11596, Feb. 23, 2023]
Source: 72 FR 38913, July 16, 2007, unless otherwise noted.
READ MORESHOW LESS
['Air Programs']
['Hazardous Air Pollutants']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.