Be Part of the Ultimate Safety & Compliance Community
Trending news, knowledge-building content, and more – all personalized to you!
Authority:Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), and 316(b) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314, 1316 (b) and (c), 1317(b); 86 Stat. 816 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.
The provisions of this subpart are applicable to discharges resulting from the production of insulation fiberglass in which molten glass is either directly or indirectly made, continuously fiberized and chemically bonded into a wool-like material.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term “cullet water” shall mean that water which is exclusively and directly applied to molten glass in order to solidify the glass.
(c) The term “advanced air emission control devices” shall mean air pollution control equipment, such as electrostatic precipitators and high energy scrubbers, that are used to treat an air discharge which has been treated initially by equipment including knock-out chambers and low energy scrubbers.
The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available:
(a) There shall be no discharge of process waste water pollutants to navigable waters, except as permitted in paragraph (b) of this section.
(b) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged in process waste water from advanced air emission control devices, when such water cannot be consumed in the process.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (kilograms per 1,000 kg of product) | ||
Phenol | 0.0006 | 0.0003 |
COD | 0.33 | .165 |
BOD5 | 0.024 | .012 |
TSS | 0.03 | .015 |
pH | ( 1) | ( 1) |
English units (pounds per 1,000 lb. of product) | ||
Phenol | 0.0006 | 0.0003 |
COD | 0.33 | .165 |
BOD5 | 0.024 | .012 |
TSS | 0.03 | .015 |
pH | ( 1) | ( 1) |
[39 FR 2565, Jan. 22, 1974; 39 FR 4760, Feb. 7, 1974]
The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters.
The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
(a) Applicability. The provisions of this section shall apply to discharges of process waste water pollutants into publicly owned treatment works except for that portion of the waste stream which constitutes cullet water.
(b) [Reserved]
[39 FR 2565, Jan. 22, 1974, as amended at 60 FR 33958, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.12 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullen and other ingredients) are mixed, melted in a furnace, and drawn vertically from a melting tank to form sheet glass.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term “cullet” shall mean any broken glass generated in the manufacturing process.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.
[60 FR 33958, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters.
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standard |
---|---|
pH | No limitation. |
TSS | Do. |
[40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33958, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology: There shall be no discharge of process waste water pollutants to navigable waters.
[44 FR 50746, Aug. 29, 1979]
The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet, and other ingredients) are mixed, melted in a furnace, and cooled by rollers to form rolled glass.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term “cullet” shall mean any broken glass generated in the manufacturing process.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.
[60 FR 33958, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters.
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standard |
---|---|
pH | No limitation. |
TSS | Do. |
[40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33958, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology: There shall be no discharge of process waste water pollutants to navigable waters.
[44 FR 50746, Aug. 29, 1979]
The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet and other ingredients) are melted in a furnace, pressed between rollers, and finally ground and polished to form plate glass.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term “cullet” shall mean any broken glass generated in the manufacturing process.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (kg/kkg of product) | ||
TSS | 2.76 | .138 |
pH | ( 1) | ( 1) |
English units (lb/ton of product) | ||
TSS | 5.52 | 2.76 |
pH | ( 1) | ( 1) |
[39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33958, June 29, 1995]
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standard |
---|---|
pH | No limitation. |
TSS | Do. |
[40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33958, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33958, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.42 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges of pollutants resulting from the process in which several mineral ingredients (sand, soda ash, limestone, dolomite, cullet, and other ingredients) are mixed, melted in a furnace, and floated on a molten tin bath to produce float glass.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (q/kkg of product) | ||
TSS | 2.00 | 2.00 |
Oil | 1.40 | 1.40 |
Phosphorus | 0.05 | .05 |
pH | ( 1) | ( 1) |
English units (lb/ton of product) | ||
TSS | 0.0040 | 0.0040 |
Oil | 0.0028 | .0028 |
Phosphorus | 0.0001 | .0001 |
pH | ( 1) | ( 1) |
[39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33958, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kg of product) | ||
Phosphorus | 0.05 | .05 |
English units (lb/ton of product) | ||
Phosphorus | 0.0001 | .0001 |
[39 FR 5714, Feb. 14, 1974, as amended at 44 FR 50746, Aug. 29, 1979]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of product) | ||
TSS | 0.70 | 0.70 |
Oil | 1.40 | 1 .40 |
Phosphorus | 0.05 | .05 |
pH | ( 1) | ( 1) |
English units (lb/ton of product) | ||
TSS | 0.0014 | 0.0014 |
Oil | 0.0028 | .0028 |
Phosphorus | 0.0001 | .0001 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33958, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.52 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges of pollutants resulting from the processes in which glass is cut and then passed through a series of processes that grind and polish the edges, bend the glass, and then temper the glass to produce side and back windows for automobiles.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
(b) The term “tempering” shall mean the process whereby glass is heated near the melting point and then rapidly cooled to increase its mechanical and thermal endurance.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (q/sq m of product) | ||
TSS | 1.95 | 1.22 |
Oil | 0.64 | .64 |
pH | ( 1) | ( 1) |
English units (lb/1,060 sq ft of product) | ||
TSS | 0.40 | 0.25 |
Oil | 0.13 | .13 |
pH | ( 1) | ( 1) |
[39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995]
Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standard |
---|---|
pH | No limitation. |
Oil | Do. |
TSS | Do. |
[40 FR 6444, Feb. 11, 1975, as amended at 60 FR 33959, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (q/sq m of product) | ||
TSS | 0.24 | 0.24 |
Oil | 0.49 | .49 |
pH | ( 1) | ( 1) |
English units (lb/1,000 sq ft of product) | ||
TSS | 0.05 | 0.05 |
Oil | 0.10 | .10 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33959, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.62 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges of pollutants resulting from the processes which laminate a plastic sheet between two layers of glass, and which prepare the glass for lamination such as cutting, bending and washing, to produce automobile windshields.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (q/sq m of product) | ||
TSS | 4.40 | 4.40 |
Oil | 1.76 | 1.76 |
Phosphorus | 1.07 | 1.07 |
pH | ( 1) | ( 1) |
English units (lb/1,000 sq ft of product) | ||
TSS | 0.90 | 0.90 |
Oil | 0.36 | .36 |
Phosphorus | 0.22 | .22 |
pH | ( 1) | ( 1) |
[39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (q/sq m of products) | ||
Phosphorus | 0.30 | .30 |
English units (lb/1,000 sq ft of product) | ||
Phosphorus | 0.06 | .06 |
[39 FR 5714, Feb. 14, 1974, as amended at 44 FR 50746, Aug. 29, 1979]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new point source subject to the provisions of this subpart:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (q/sq m of product) | ||
TSS | 0.88 | 0.88 |
Oil | 1.76 | 1.76 |
Phosphorus | 0.30 | .30 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of product) | ||
TSS | 0.18 | 0.18 |
Oil | 0.36 | .36 |
Phosphorus | 0.06 | .06 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.
[60 FR 33959, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.72 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and mechanically processed into glass containers.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.
(c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
Oil | 60.0 | 30.0 |
TSS | 140.0 | 70.0 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.06 | 0.03 |
TSS | 0.14 | 0.07 |
pH | ( 1) | ( 1) |
[40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
Oil | 1.6 | 0.8 |
TSS | 1.6 | 0.8 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.0016 | 0.0008 |
TSS | 0.0016 | 0.0008 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established.
Pollutant or pollutant property | Pretreatment standards | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 No limitation. | ||
Metric units (g/kkg of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil (mineral) | 60.0 | 30.0 |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil (mineral) | 0.06 | 0.03 |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
[40 FR 2956, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.82 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and glass tubing mechanically drawn from the furnace horizontally by means of the Danner process, which requires the intermittent quenching of cullet.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.
(c) The term “cullet” shall mean any excess glass generated in the manufacturing process.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
TSS | 460.0 | 230.0 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
TSS | 0.46 | 0.23 |
pH | ( 1) | ( 1) |
[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
TSS | 0.4 | 0.2 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
TSS | 0.0004 | 0.0002 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standard |
---|---|
pH | No limitation. |
TSS | Do. |
[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.102 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and processed into television picture tube envelopes.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.
(c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT). (The fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the entire process waste water stream):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
Oil | 260.0 | 130.0 |
TSS | 300.0 | 150.0 |
Fluoride | 140.0 | 70.0 |
Lead | 39.0 | 4.5 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.26 | 0.13 |
TSS | 0.30 | 0.15 |
Fluoride | 0.14 | 0.07 |
Lead | 0.009 | 0.0045 |
pH | ( 1) | ( 1) |
[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of furnace pull) | ||
Fluoride | 120.0 | 60.0 |
Lead | 0.9 | 0.45 |
English units (lb/1,000 lb of furnace pull) | ||
Fluoride | 0.12 | 0.06 |
Lead | 0.0009 | 0.00045 |
[44 FR 50747, Aug. 29, 1979]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the entire process waste water stream):
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 Within the range 6.0 to 9.0. | ||
Metric units (g/kkg of furnace pull) | ||
Oil | 260.0 | 130.0 |
TSS | 260.0 | 130.0 |
Fluoride | 120.0 | 60.0 |
Lead | 30.9 | 0.45 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.26 | 0.13 |
TSS | 0.26 | 0.13 |
Fluoride | 0.12 | 0.06 |
Lead | 0.0009 | 0.00045 |
pH | ( 1) | ( 1) |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established.
Pollutant or pollutant property | Pretreatment standards | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 No limitation. | ||
Metric units (g/kkg of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil (mineral) | 260.0 | 130.0 |
TSS | ( 1) | ( 1) |
Fluoride | 120.0 | 60.0 |
Lead | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil | 0.26 | 0.13 |
TSS | ( 1) | ( 1) |
Fluoride | 0.12 | 0.06 |
Lead | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
[40 FR 2957, Jan. 16, 1975, as amended at 60 FR 33959, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.112 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges resulting from the processes by which (a) raw materials are melted in a furnace and mechanically processed into incandescent lamp envelopes or (b) incandescent lamp envelopes are etched with hydrofluoric acid to produce frosted envelopes.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “furnace pull” shall mean that amount of glass drawn from the glass furnace or furnaces.
(c) The term “oil” shall mean those components of a waste water amenable to measurement by the technique or techniques described in the most recent addition of “Standard Methods” for the analysis of grease in polluted waters, waste waters, and effluents, such as “Standard Methods,” 13th Edition, 2nd Printing, page 407.
(d) The term “product frosted” shall mean that portion of the “furnace pull” associated with the fraction of finished incandescent lamp envelopes which is frosted; this quantity shall be calculated by multiplying “furnace pull” by the fraction of finished incandescent lamp envelopes which is frosted.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of furnace pull) | ||
Oil | 230.0 | 115.0 |
TSS | 230.0 | 115.0 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.23 | 0.115 |
TSS | 0.23 | 0.115 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of product frosted) | ||
Fluoride | 230.0 | 115.0 |
Ammonia | ( 1) | ( 1) |
TSS | 460.0 | 230.0 |
pH | ( 2) | ( 2) |
English units (lb/1000 lb of product frosted) | ||
Fluoride | 0.23 | 0.115 |
Ammonia | ( 1) | ( 1) |
TSS | 0.46 | 0.23 |
pH | ( 2) | ( 2) |
1 No limitation. 2 Within the range 6.0 to 9.0. |
[40 FR 2959, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995]
Except as provided in §§125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
(a) [Reserved]
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of product frosted) | ||
Fluoride | 104.0 | 52.0 |
Ammonia | 240.0 | 120.0 |
English units (lb/1,000 lb of product frosted) | ||
Fluoride | 0.104 | 0.052 |
Ammonia | 0.24 | 0.12 |
[51 FR 25001, July 9, 1986]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(a) Any manufacturing plant which produces incandescent lamp envelopes shall meet the following limitations with regard to the forming operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of furnace pull) | ||
Oil | 90.0 | 45.0 |
TSS | 90.0 | 45.0 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil | 0.09 | 0.045 |
TSS | 0.09 | 0.045 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
(b) Any manufacturing plant which frosts incandescent lamp envelopes shall meet the following limitations with regard to the finishing operations.
Effluent characteristic | Effluent limitations | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Metric units (g/kkg of product frosted) | ||
Fluoride | 104.0 | 52.0 |
Ammonia | 240.0 | 120.0 |
TSS | 80.0 | 40.0 |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of product frosted) | ||
Fluoride | 0.104 | 0.052 |
Ammonia | 0.24 | 0.12 |
TSS | 0.08 | 0.04 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart. Because of the recognition that animal and vegetable oils can be adequately removed in a publicly owned treatment works, whereas mineral oil may not be readily removed and may pass through untreated, two separate limitations are established.
Pollutant or pollutant property | Pretreatment standards | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 No limitation. | ||
Metric units (g/kkg of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil (mineral) | 230.0 | 115.0 |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of furnace pull) | ||
Oil (animal and vegetable) | ( 1) | ( 1) |
Oil (mineral) | 0.23 | 0.115 |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
Metric units (g/kkg of product frosted) | ||
Fluoride | 104.0 | 52.0 |
Ammonia | ( 1) | ( 1) |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
English units (lb/1,000 lb of product frosted) | ||
Fluoride | 0.104 | 0.052 |
Ammonia | ( 1) | ( 1) |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
[40 FR 2959, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995]
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in §401.16) in §426.122 of this subpart for the best practicable control technology currently available (BPT).
[51 FR 25000, July 9, 1986]
The provisions of this subpart are applicable to discharges resulting from the process by which raw materials are melted in a furnace and processed by hand into pressed or blown glassware. This includes those plants which:
(a) Produce leaded glass and employ hydrofluoric acid finishing techniques,
(b) Produce non-leaded glass and employ hydrofluoric acid finishing techniques, or
(c) Produce leaded or non-leaded glass and do not employ hydrofluoric acid finishing techniques.
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, employs hydrofluoric acid finishing techniques, and discharges greater than 50 gallons per day of process waste water, shall meet the following limitations.
Effluent characteristic | Effluent limitations |
---|---|
Lead | No limitation. |
Fluoride | Do. |
TSS | Do. |
pH | Do. |
(b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations |
---|---|
Fluoride | No limitation. |
TSS | Do. |
pH | Do. |
(c) Any plant which melts raw materials, produces leaded or non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and does not employ hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations |
---|---|
TSS | No limitation. |
pH | Do. |
[40 FR 2960, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995]
The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:
(a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Lead | 0.2 | 0.1 |
Fluoride | 26.0 | 13.0 |
(b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Fluoride | 26.0 | 13.0 |
[44 FR 50747, Aug. 29, 1979, as amended at 51 FR 25001, July 9, 1986]
The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
(a) Any plant which melts raw materials, produces hand pressed or blown leaded glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Lead | 0.2 | 0.1 |
Fluoride | 26.0 | 13.0 |
TSS | 20.0 | 10.0 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
(b) Any plant which melts raw materials, produces non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and employs hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
Fluoride | 26.0 | 13.0 |
TSS | 20.0 | 10.0 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
(c) Any plant which melts raw materials, produces leaded or non-leaded hand pressed or blown glassware, discharges greater than 50 gallons per day of process waste water, and does not employ hydrofluoric acid finishing techniques shall meet the following limitations.
Effluent characteristic | Effluent limitations (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
TSS | 20.0 | 10.0 |
pH | ( 1) | ( 1) |
1 Within the range 6.0 to 9.0. |
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.
Pollutant or pollutant property | Pretreatment standards (mg/l) | |
---|---|---|
Maximum for any 1 day | Average of daily values for 30 consecutive days shall not exceed - | |
1 No limitation. | ||
(a): | ||
Fluoride | 26.0 | 13.0 |
Lead | ( 1) | ( 1) |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
(b): | ||
Fluoride | 26.0 | 13.0 |
Lead | ( 1) | ( 1) |
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
(c): | ||
TSS | ( 1) | ( 1) |
pH | ( 1) | ( 1) |
[40 FR 2960, Jan. 16, 1975, as amended at 60 FR 33960, June 29, 1995]