['Air Programs']
['Greenhouse Gases']
05/22/2023
...
For each stack system for which you use the “stack test method” to calculate annual emissions, you must measure the following: | If emissions are detected intermittently, use the following procedures: | If emissions are not detected, use the following procedures: |
---|---|---|
Expected By-products: CF4 C2F6 CHF3 CH2F2 CH3F | Use the measured concentration for “Xksm” in Equation I-18 when available and use one-half of the field detection limit you determined for the fluorinated GHG according to §98.94(j)(2) for the value of “Xksm” when the fluorinated GHG is not detected. | Use one-half of the field detection limit you determined for the fluorinated GHG according to §98.94(j)(2) for the value of “Xksm” in Equation I-18. |
Possible By-products: C3F8 C4F6 c-C4F8 C5F8 | Use the measured concentration for “Xksm” in Equation I-18 when available and use one-half of the field detection limit you determined for the fluorinated GHG according to §98.94(j)(2) for the value of “Xksm” when the fluorinated GHG is not detected. | Assume zero emissions for that fluorinated GHG for the tested stack system. |
[78 FR 68234, Nov. 13, 2013]
['Air Programs']
['Greenhouse Gases']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.