['Air Programs']
['Hazardous Air Pollutants']
12/26/2024
...
As stated in §63.9991, you must comply with the following applicable emission limits:
If your EGU is in this
subcategory . . . | For the following
pollutants . . . | You must meet the following emission limits and work
practice standards . . . | Using these requirements, as appropriate (e.g., specified sampling volume or test run duration) and limitations with the test
methods in Table 5 to this Subpart . . . |
---|---|---|---|
1 Gross output. 2 Incorporated by reference, see §63.14. 3 You may not use the alternate SO2 limit if your EGU does not have some form of FGD system (or, in the case of IGCC EGUs, some other acid gas removal system either upstream or downstream of the combined cycle block) and SO2 CEMS installed. 4 Duct burners on syngas; gross output. 5 Duct burners on natural gas; gross output. | |||
1. Coal-fired unit not low rank virgin coal | a. Filterable particulate matter (PM) | 9.0E-2 lb/MWh 1 | Collect a minimum of 4 dscm per run. |
OR | OR | ||
Total non-Hg HAP metals | 6.0E-2 lb/GWh | Collect a minimum of 4 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 3 dscm per run. | ||
Antimony (Sb) | 8.0E-3 lb/GWh | ||
Arsenic (As) | 3.0E-3 lb/GWh | ||
Beryllium (Be) | 6.0E-4 lb/GWh | ||
Cadmium (Cd) | 4.0E-4 lb/GWh | ||
Chromium (Cr) | 7.0E-3 lb/GWh | ||
Cobalt (Co) | 2.0E-3 lb/GWh | ||
Lead (Pb) | 2.0E-2 lb/GWh | ||
Manganese (Mn) | 4.0E-3 lb/GWh | ||
Nickel (Ni) | 4.0E-2 lb/GWh | ||
Selenium (Se) | 5.0E-2 lb/GWh | ||
b. Hydrogen chloride (HCl) | 1.0E-2 lb/MWh | For Method 26A at appendix A-8 to part 60 of this chapter, collect a minimum of 3 dscm per run. For ASTM D6348-03 2 or Method 320 at appendix A to part 63 of this chapter, sample for a minimum of 1 hour. | |
OR | |||
Sulfur dioxide (SO2) 3 | 1.0 lb/MWh | SO2 CEMS. | |
c. Mercury (Hg) | 3.0E-3 lb/GWh | Hg CEMS or sorbent trap monitoring system only. | |
2. Coal-fired units low rank virgin coal | a. Filterable particulate matter (PM) | 9.0E-2 lb/MWh 1 | Collect a minimum of 4 dscm per run. |
OR | OR | ||
Total non-Hg HAP metals | 6.0E-2 lb/GWh | Collect a minimum of 4 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 3 dscm per run. | ||
Antimony (Sb) | 8.0E-3 lb/GWh | ||
Arsenic (As) | 3.0E-3 lb/GWh | ||
Beryllium (Be) | 6.0E-4 lb/GWh | ||
Cadmium (Cd) | 4.0E-4 lb/GWh | ||
Chromium (Cr) | 7.0E-3 lb/GWh | ||
Cobalt (Co) | 2.0E-3 lb/GWh | ||
Lead (Pb) | 2.0E-2 lb/GWh | ||
Manganese (Mn) | 4.0E-3 lb/GWh | ||
Nickel (Ni) | 4.0E-2 lb/GWh | ||
Selenium (Se) | 5.0E-2 lb/GWh | ||
b. Hydrogen chloride (HCl) | 1.0E-2 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
OR | |||
Sulfur dioxide (SO2) 3 | 1.0 lb/MWh | SO2 CEMS. | |
c. Mercury (Hg) | 4.0E-2 lb/GWh | Hg CEMS or sorbent trap monitoring system only. | |
3. IGCC unit | a. Filterable particulate matter (PM) | 7.0E-2 lb/MWh 4 9.0E-2 lb/MWh 5 | Collect a minimum of 1 dscm per run. |
OR | OR | ||
Total non-Hg HAP metals | 4.0E-1 lb/GWh | Collect a minimum of 1 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 2 dscm per run. | ||
Antimony (Sb) | 2.0E-2 lb/GWh | ||
Arsenic (As) | 2.0E-2 lb/GWh | ||
Beryllium (Be) | 1.0E-3 lb/GWh | ||
Cadmium (Cd) | 2.0E-3 lb/GWh | ||
Chromium (Cr) | 4.0E-2 lb/GWh | ||
Cobalt (Co) | 4.0E-3 lb/GWh | ||
Lead (Pb) | 9.0E-3 lb/GWh | ||
Manganese (Mn) | 2.0E-2 lb/GWh | ||
Nickel (Ni) | 7.0E-2 lb/GWh | ||
Selenium (Se) | 3.0E-1 lb/GWh | ||
b. Hydrogen chloride (HCl) | 2.0E-3 lb/MWh | For Method 26A, collect a minimum of 1 dscm per run; for Method 26 at appendix A-8 to part 60 of this chapter, collect a minimum of 120 liters per run. For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
OR | |||
Sulfur dioxide (SO2) 3 | 4.0E-1 lb/MWh | SO2 CEMS. | |
c. Mercury (Hg) | 3.0E-3 lb/GWh | Hg CEMS or sorbent trap monitoring system only. | |
4. Liquid oil-fired unit - continental (excluding limited-use liquid oil-fired subcategory units) | a. Filterable particulate matter (PM) | 3.0E-1 lb/MWh 1 | Collect a minimum of 1 dscm per run. |
OR | OR | ||
Total HAP metals | 2.0E-4 lb/MWh | Collect a minimum of 2 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 2 dscm per run. | ||
Antimony (Sb) | 1.0E-2 lb/GWh | ||
Arsenic (As) | 3.0E-3 lb/GWh | ||
Beryllium (Be) | 5.0E-4 lb/GWh | ||
Cadmium (Cd) | 2.0E-4 lb/GWh | ||
Chromium (Cr) | 2.0E-2 lb/GWh | ||
Cobalt (Co) | 3.0E-2 lb/GWh | ||
Lead (Pb) | 8.0E-3 lb/GWh | ||
Manganese (Mn) | 2.0E-2 lb/GWh | ||
Nickel (Ni) | 9.0E-2 lb/GWh | ||
Selenium (Se) | 2.0E-2 lb/GWh | ||
Mercury (Hg) | 1.0E-4 lb/GWh | For Method 30B at appendix A-8 to part 60 of this chapter sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be < 1/2 the standard. | |
b. Hydrogen chloride (HCl) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
c. Hydrogen fluoride (HF) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
5. Liquid oil-fired unit - non-continental (excluding limited-use liquid oil-fired subcategory units) | a. Filterable particulate matter (PM) | 2.0E-1 lb/MWh 1 | Collect a minimum of 1 dscm per run. |
OR | OR | ||
Total HAP metals | 7.0E-3 lb/MWh | Collect a minimum of 1 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 3 dscm per run. | ||
Antimony (Sb) | 8.0E-3 lb/GWh | ||
Arsenic (As) | 6.0E-2 lb/GWh | ||
Beryllium (Be) | 2.0E-3 lb/GWh | ||
Cadmium (Cd) | 2.0E-3 lb/GWh | ||
Chromium (Cr) | 2.0E-2 lb/GWh | ||
Cobalt (Co) | 3.0E-1 lb/GWh | ||
Lead (Pb) | 3.0E-2 lb/GWh | ||
Manganese (Mn) | 1.0E-1 lb/GWh | ||
Nickel (Ni) | 4.1E0 lb/GWh | ||
Selenium (Se) | 2.0E-2 lb/GWh | ||
Mercury (Hg) | 4.0E-4 lb/GWh | For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be < 1/2 the standard. | |
b. Hydrogen chloride (HCl) | 2.0E-3 lb/MWh | For Method 26A, collect a minimum of 1 dscm per run;for Method 26, collect a minimum of 120 liters per run. For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
c. Hydrogen fluoride (HF) | 5.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run.For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
6. Solid oil-derived fuel-fired unit | a. Filterable particulate matter (PM) | 3.0E-2 lb/MWh 1 | Collect a minimum of 1 dscm per run. |
OR | OR | ||
Total non-Hg HAP metals | 6.0E-1 lb/GWh | Collect a minimum of 1 dscm per run. | |
OR | OR | ||
Individual HAP metals: | Collect a minimum of 3 dscm per run. | ||
Antimony (Sb) | 8.0E-3 lb/GWh | ||
Arsenic (As) | 3.0E-3 lb/GWh | ||
Beryllium (Be) | 6.0E-4 lb/GWh | ||
Cadmium (Cd) | 7.0E-4 lb/GWh | ||
Chromium (Cr) | 6.0E-3 lb/GWh | ||
Cobalt (Co) | 2.0E-3 lb/GWh | ||
Lead (Pb) | 2.0E-2 lb/GWh | ||
Manganese (Mn) | 7.0E-3 lb/GWh | ||
Nickel (Ni) | 4.0E-2 lb/GWh | ||
Selenium (Se) | 6.0E-3 lb/GWh | ||
b. Hydrogen chloride (HCl) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 2 or Method 320, sample for a minimum of 1 hour. | |
OR | |||
Sulfur dioxide (SO2) 3 | 1.0 lb/MWh | SO2 CEMS. | |
c. Mercury (Hg) | 2.0E-3 lb/GWh | Hg CEMS or Sorbent trap monitoring system only. |
[81 FR 20190, Apr. 6, 2016]
READ MORESHOW LESS
['Air Programs']
['Hazardous Air Pollutants']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.