['Drug and Alcohol Testing - DOT']
['Alcohol testing - Motor Carrier']
04/11/2025
...
NHTSA product lists
Sec. 40.233 requires that external calibration checks be performed on Evidential Breath Testing devices (EBTs). Only calibration devices appearing on the National Highway Traffic Safety Administration’s “Conforming Products List of Calibrating Units for Breath Alcohol Testers” may be used.
The latest list of calibrating units appeared in the June 25, 2007, Federal Register.
Agency Contact: | Ms. J. De Carlo Ciccel
Office of Behavioral Safety Research, NTI-130 National Highway Traffic Safety Administration 1200 New Jersey Avenue, SE Washington, DC 20590 Telephone: (202) 366-1694 |
Following is the current list of approved calibrating units:
Conforming products list of calibrating units for breath alcohol testers (manufacturer and calibrating unit) 1
1Infra-red (IR) and fuel cell breath testers may be calibrated
with either wet bath or dry gas CUs. However, it is inadvisable to use dry gas
CUs when calibrating gas chromatograph EBTs. *Six instruments marked with an asterisk (*) meet the Model Specifications in 49 FR 48864 (December 14, 1984), i.e., instruments tested at 0.050, 0.100, and 0.150. Instruments not marked with an asterisk meet the model specifications detailed in this notice, and were tested at 0.020, 0.040, 0.080, and 0.160 BrAC. | ||
Manufacturers | Type of device | |
Dry gas | Wet bath | |
1. Airgas, Inc. (Formerly known as: Gateway Airgas, AG
Specialty Gas, or Acetylene Gas Co.), St. Louis, MO Ethanol Breath Alcohol Standard 103 parts per million (ppm)/108 Liters (L) 270 ppm/30L | X X X | |
2. Air Liquide CALGAZ, Cambridge, MD 115 ppm/34L 115 ppm/105L 230 ppm/34L 230 ppm/105L 260.5 ppm/58L 260.5 ppm/537L 260.5 ppm/15L | X X X X X X X | |
3. CMI, Inc., Owensboro, KY Toxitest II | X | |
4. Davtech Analytical Services, Canada CALWAVE dT-100 | X | |
5. Guth Laboratories, Inc., Harrisburg, PA Model 34C Simulator (variations: Model 34C Cal DOJ, 34-C-FM, and 34C-NPAS) Model 3412 Model 10-4 and 10-4D Model 10-4D Revision A Model 1214 Model 2100 (formerly Model 210021) Model 2100 Revision A 590 | X X X X X X X X | |
6. Intoximeters, Inc., St. Louis, MO Alco Breath Alcohol Standards* | X | |
7. Lion Laboratories, Cardiff, Wales, UK (a subsidiary of
CMI, Inc.) AlcoCal Breath Alcohol Standard | X | |
8. Liquid Technology Corp., Orlando, FL Ethanol-in-Nitrogen | X | |
9. Luckey Laboratories, Inc., San Bernardino, CA Simulator* | X | |
10. National Draeger, Inc., Durango, CO Mark II-A Alcotest CU 34 | X X | |
11. PLD of Florida, Inc., Rockledge, FL BA 500 | X | |
12. Protection Devices, Inc., U.S. Alcohol Testing, Inc.,
Rancho Cucamonga, CA LS34 Model 6100* | X | |
13. RepCo Marketing, Inc., Raleigh, NC AS-1 Model 3402C Model 3402C-2K | X X X | |
14. Scott Specialty Gases, Inc., Plumsteadville, PA Model EBS™ Gaseous Ethanol Breath Standard Scotty 28 0.040 BAC/28L Scotty 28 0.045 BAC/28L Scotty 28 0.080 BAC/28L Scotty 28 0.100 BAC/28L Scotty 28 0.105 BAC/28L | X X X X X X | |
15. Smith & Wesson Electronic Co., Springfield,
MA Mark II-A Simulator* | X | |
16. Systems Innovation, Inc., Hallstead, PA True-Test MD 901* | X | |
17. U.S. Alcohol Testing, Rancho Cucamonga, CA Alco-Simulator 2000* Alco-Simulator 61000 | X X |
['Drug and Alcohol Testing - DOT']
['Alcohol testing - Motor Carrier']
UPGRADE TO CONTINUE READING
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.