In addition to the records required by §98.3(g), you must retain the records specified in paragraphs (a) through (c) of this section for each soda ash manufacturing line.
(a) If a CEMS is used to measure CO2 emissions, then you must retain under this subpart the records required for the Tier 4 Calculation Methodology specified in subpart C of this part and the information listed in this paragraph (a):
(1) Monthly production of soda ash (tons)
(2) Monthly consumption of trona or liquid alkaline feedstock (tons)
(3) Annual operating hours (hours).
(b) If a CEMS is not used to measure emissions, then you must retain records for the information listed in this paragraph (b):
(1) Records of all analyses and calculations conducted for determining all reported data as listed in §98.296(b).
(2) If using Equation CC–1 or CC–2 of this subpart, weekly inorganic carbon content factor of trona or soda ash, depending on method chosen, as measured by the applicable method in §98.294(b) (percent by weight expressed as a decimal fraction).
(3) Annual operating hours for each manufacturing line used to produce soda ash (hours).
(4) You must document the procedures used to ensure the accuracy of the monthly trona consumption or soda ash production measurements including, but not limited to, calibration of weighing equipment and other measurement devices. The estimated accuracy of measurements made with these devices must also be recorded, and the technical basis for these estimates must be provided.
(5) If you produce soda ash using the liquid alkaline feedstock process and use the site-specific emission factor method to estimate emissions (§98.293(b)(3)) then you must also retain the following relevant information:
(i) Records of performance test results.
(ii) You must document the procedures used to ensure the accuracy of the annual average vent flow measurements including, but not limited to, calibration of flow rate meters and other measurement devices. The estimated accuracy of measurements made with these devices must also be recorded, and the technical basis for these estimates must be provided.
(c) Verification software records. You must keep a record of the file generated by the verification software specified in §98.5(b) for the applicable data specified in paragraphs (c)(1) through (4) of this section. Retention of this file satisfies the recordkeeping requirement for the data in paragraphs (c)(1) through (4) of this section
(1) Inorganic carbon content in trona input, from the carbon analysis results for month (percent by weight, expressed as a decimal fraction) (Equation CC-1 of §98.293).
(2) Mass of trona input in month (tons) (Equation CC-1).
(3) Inorganic carbon content in soda ash output, from the carbon analysis results for month (percent by weight, expressed as a decimal fraction) (Equation CC-2 of §98.293).
(4) Mass of soda ash output in month (tons) (Equation CC-2).
[74 FR 56470, Oct. 30, 2009; 79 FR 63798, Oct. 24, 2014]
READ MORESHOW LESS
['Air Programs']
['Greenhouse Gases']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.