['Air Programs']
['Mobile Emission Sources']
08/01/2024
...
The durability-related requirements of this section apply for vehicles subject to refueling standards under this subpart. Refer to the provisions of §§86.1801 and 86.1813 to determine applicability of the refueling standards to different classes of vehicles. Diesel-fueled vehicles may be exempt from the requirements of this section under §86.1829.
(a) Durability program objective. The durability program must predict an expected in-use emission deterioration rate and emission level that effectively represents a significant majority of the distribution of emission levels and deterioration in actual use over the full useful life of candidate in-use vehicles of each vehicle design which uses the durability program.
(b) Required durability demonstration. Manufacturers must conduct a durability demonstration which satisfies the provisions of either paragraph (c), (d), or (e) of this section.
(c) Whole vehicle refueling durability demonstration. The following procedures must be used when conducting a whole vehicle durability demonstration:
(1) Mileage accumulation must be conducted using the SRC or a road cycle approved under the provisions of §86.1823-08(e)(1).
(2) Mileage accumulation must be conducted for either:
(i) The applicable full useful life mileage period specified in §86.1805, or
(ii) At least 75 percent of the full useful life mileage. In which case, the manufacturer must calculate a df calculated according to the procedures of paragraph (f)(1)(ii) of this section, except that the DF must be based upon a line projected to the full-useful life mileage using the upper 80 percent statistical confidence limit calculated from the emission data.
(3) The manufacturer must conduct at least one refueling emission test at each of the five different mileage points selected using good engineering judgement. The required testing must include testing at 5,000 miles and at the highest mileage point run during mileage accumulation (e.g. the full useful life mileage). Additional testing may be conducted by the manufacturer using good engineering judgement.
(d) Bench aging refueling durability procedures. Manufacturers may use bench procedures designed, using good engineering judgement, to evaluate the emission deterioration of evaporative/refueling control systems. Manufacturers may base the bench procedure on an evaluation the following potential causes of evaporative/refueling emission deterioration:
(1) Cycling of canister loading due to diurnal and refueling events;
(2) Use of various commercially available fuels, including the Tier 2 requirement to include alcohol fuel;
(3) Vibration of components;
(4) Deterioration of hoses, etc. due to environmental conditions; and
(5) Deterioration of fuel cap due to wear.
(e) Combined whole-vehicle and bench-aging programs. Manufacturers may combine the results of whole vehicle aging and bench aging procedures using good engineering judgement.
(f) [Reserved]
(g) Calculation of a deterioration factor. The manufacturer must calculate a deterioration factor which is applied to the evaporative emission results of the emission data vehicles. The deterioration factor must be based on a linear regression, or an other regression technique approved in advance by the Administrator. The DF will be calculated to be the difference between the full life mileage evaporative level minus the stabilized mileage (e.g., 4000-mile) evaporative level from the regression analysis. The full useful life regressed emission value, the stabilized mileage regressed emission value, and the DF result must be rounded to the same precision and using the same procedures as the raw emission results according to the provisions of §86.1837-01. Calculated DF values of less than zero must be changed to zero for the purposes of this paragraph.
(h) Emission component durability. The manufacturer shall use good engineering judgment to determine that all emission-related components are designed to operate properly for the full useful life of the vehicles in actual use.
(i) If EPA determines based on IUVP data or other information that the durability procedure does not achieve the durability objective of paragraph (a) of this section, EPA may withdraw approval to use the durability procedure or condition approval on modifications to the durability procedure. Such withdrawal or conditional approval will apply to future applications for certification and to the portion of the manufacturer's product line (or the entire product line) that the Administrator determines to be affected. Prior to such a withdrawal the Administrator will give the manufacturer a preliminary notice at least 60 days prior to the final decision. During this period, the manufacturer may submit technical discussion, statistical analyses, additional data, or other information which is relevant to the decision. The Administrator will consider all information submitted by the deadline before reaching a final decision.
(j) Any manufacturer may request a hearing on the Administrator's withdrawal of approval in paragraph (i) of this section. The request must be in writing and must include a statement specifying the manufacturer's objections to the Administrator's determinations, and data in support of such objection. If, after review of the request and supporting data, the Administrator finds that the request raises a substantial factual issue, she/he must provide the manufacturer a hearing in accordance with §86.1853-01 with respect to such issue.
[71 FR 2835, Jan. 17, 2006; 89 FR 28177, Apr. 18, 2024]
READ MORESHOW LESS
['Air Programs']
['Mobile Emission Sources']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.