| Canister type | Test condition | Test atmosphere | Number of tests | Maximum allowable penetratin (parts per million) | Minimum service life (minutes) 1 | ||
|---|---|---|---|---|---|---|---|
| Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | |||||
| Acid gas | As received | SO2 | 20,000 | 64 | 3 | 5 | 12 |
| Equilibrated | Cl2 | 20,000 | 64 | 3 | 5 | 12 | |
| SO2 | 20,000 | 32 | 4 | 5 | 12 | ||
| Cl2 | 20,000 | 32 | 4 | 5 | 12 | ||
| Organic vapor | As received | CCl4 | 20,000 | 64 | 3 | 5 | 12 |
| Equilibrated | CCl4 | 20,000 | 32 | 4 | 5 | 12 | |
| Ammonia | As received | NH3 | 30,000 | 64 | 3 | 50 | 12 |
| Equilibrated | NH3 | 30,000 | 32 | 4 | 50 | 12 | |
| Carbon monoxide | As received | CO | 20,000 | 4 64 | 2 | (3) | 60 |
| Equilibrated | CO | 5,000 | 2 32 | 3 | (3) | 60 | |
| CO | 3,000 | 2 32 | 3 | (3) | 60 | ||
| Combination of 2 or 3 of above types 5 | |||||||
| Combination of all above types 6 | |||||||
| 1 Minimum life will be determined at the indicated penetration. 2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C. 3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time. 4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C. 5 Test conditions and requirements will be applicable as shown in this table. 6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min. | |||||||
| Canister type | Test condition | Test atmosphere | Number of tests | Maximum allowable penetration (parts per million) | Minimum service life (minutes) 1 | ||
|---|---|---|---|---|---|---|---|
| Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | |||||
| Acid gas | As received Equilibrated | SO2 | 50,000 | 64 | 3 | 5 | 12 |
| Cl2 | 5,000 | 64 | 3 | 5 | 12 | ||
| SO2 | 5,000 | 32 | 4 | 5 | 12 | ||
| Cl2 | 5,000 | 32 | 4 | 5 | 12 | ||
| Organic vapor | As received Equilibrated | CCl4 | 5,000 | 64 | 3 | 5 | 12 |
| CCl4 | 5,000 | 32 | 4 | 5 | 12 | ||
| Ammonia | As received Equilibrated | NH3 | 5,000 | 64 | 3 | 50 | 12 |
| As received Equilibrated | NH3 | 5,000 | 32 | 4 | 50 | 12 | |
| Carbon monoxide | As received | CO | 20,000 | 2 64 | 2 | (3) | 60 |
| CO | 5,000 | 4 32 | 3 | (3) | 60 | ||
| CO | 3,000 | 2 32 | 3 | (3) | 60 | ||
| Combination of 2 or 3 of above types 5 | |||||||
| Combination of all above types 6 | |||||||
| 1 Minimum life will be determined at the indicated penetration. 2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C. 3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time. 4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C. 5 Test conditions and requirements will be applicable as shown in this table. 6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min. | |||||||
| Canister type | Test condition | Test atmosphere | Number of tests | Maximum allowable penetration (parts per million) | Minimum service life (minutes) 1 | ||
|---|---|---|---|---|---|---|---|
| Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | |||||
| Acid gas | As received | SO2 | 5,000 | 64 | 3 | 5 | 12 |
| Equilibrated | Cl2 | 5,000 | 64 | 3 | 5 | 12 | |
| SO2 | 5,000 | 32 | 4 | 5 | 12 | ||
| Cl2 | 5,000 | 32 | 4 | 5 | 12 | ||
| Organic vapor | As received | CCl4 | 5,000 | 64 | 3 | 5 | 12 |
| Equilibrated | CCl4 | 5,000 | 32 | 4 | 5 | 12 | |
| Ammonia | As received | NH3 | 5,000 | 64 | 3 | 50 | 12 |
| Equilibrated | NH3 | 5,000 | 32 | 4 | 50 | 12 | |
| Carbon monoxide | As received | CO | 10,000 | 2 32 | 2 | (3) | 4 60 |
| CO | 5,000 | 5 32 | 3 | (3) | 60 | ||
| CO | 3,000 | 2 32 | 3 | (3) | 60 | ||
| 1 Minimum life will be determined at the indicated penetration. 2 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere will be 25 ±2.5 °C. 3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time. 4 If effluent temperature exceeds 100 °C during this test, the escape gas mask shall be equipped with an effective heat exchanger. 5 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C. | |||||||
['Personal Protective Equipment']
['Respiratory Protection']
UPGRADE TO CONTINUE READING
ezExplanations
Results Aided by AI
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2026 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.