(a) Test procedure. (1) The enclosure shall be internally pressurized to a minimum of 150 psig and the pressure maintained for a minimum of 10 seconds.
(2) Following the pressure hold, the pressure shall be removed and the pressurizing agent removed from the enclosure.
(b) Acceptable performance. (1) The enclosure during pressurization shall not exhibit—
(i) Leakage through welds or casting; or
(ii) Rupture of any part that affects the explosion-proof integrity of the enclosure.
(2) The enclosure following removal of the pressurizing agent shall not exhibit—
(i) Visible cracks in welds;
(ii) Permanent deformation exceeding 0.040 inches per linear foot; or
(iii) Clearances, in excess of those specified in this subpart, along accessible flame-arresting paths, following any necessary retightening of fastenings.
['Specialized Industries']
['Mining']
UPGRADE TO CONTINUE READING
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.