...
(a) Initial compliance status report. The owner or operator shall submit as part of the Initial Compliance Status Report specified in §65.5(d) the information recorded in §65.66(a), (b), and (c), as applicable.
(b) Process change.(1) Whenever a process change, as described in §65.63(f), is made that causes a Group 2A or 2B process vent to become a Group 1 process vent or a Group 2B process vent to become a Group 2A process vent, the owner or operator shall either submit a report within 60 days after the performance test or group determination or submit a report included as part of the next periodic report. The report shall include the following information:
(i) A description of the process change;
(ii) The results of the recalculation of the flow rate, organic HAP or TOC concentration, and/or TRE index value required under §65.63(f) and recorded under §65.66(d); and
(iii) A statement that the owner or operator will comply with the provisions of §65.63 by the schedules specified in §65.63(f)(4) through (6).
(2) For process vents that become Group 1 process vents after a process change requiring a performance test to be conducted for the control device being used as specified in subpart G of this part, the owner or operator shall specify that the performance test has become necessary due to a process change. This specification shall be made in the notification to the Administrator of the intent to conduct a performance test as provided in §65.164(b)(1).
(3) Whenever a process change as described in §65.63(f) is made that changes the group status of a process vent from Group 1 to Group 2A, or from Group 1 to Group 2B, or from Group 2A to Group 2B, the owner or operator shall include a statement in the next periodic report after the process change that a process change has been made and the new group status of the process vents.
(4) The owner or operator is not required to submit a report of a process change if one of the following conditions is met:
(i) The change does not meet the definition of a process change in §65.63(f); or
(ii) For a Group 2B process vent, the vent stream flow rate is recalculated according to §65.63(f) and the recalculated value is less than 0.011 standard cubic meter per minute (0.40 standard cubic foot per minute); or
(iii) For a Group 2B process vent, the organic HAP or TOC concentration of the vent stream is recalculated according to §65.63(f), and the recalculated value is less than the applicable value in table 1 to this subpart; or
(iv) For a Group 2B process vent, the TRE index value is recalculated according to §65.63(f) and the recalculated value is greater than 4.0.
(c) Parameters for Group 2A without a recovery device. An owner or operator of a Group 2A process vent maintaining a TRE index value greater than 1.0 without using a recovery device shall report the information specified in the approved plan under §65.63(d).