(a) In conducting the performance tests required in �60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in �60.8(b).
(b) The owner or operator shall determine compliance with the particulate matter, sulfur dioxide (SO2), and visible emission standards in ��60.182, 60.183, and 60.184 as follows:
(1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).
(2) The continuous monitoring system of �60.185(a)(2) shall be used to determine the SO2 concentrations on a dry basis. The sampling time for each run shall be 2 hours, and the average SO2 concentration for the 2-hour period shall be computed as in �60.185(b). The monitoring system drift during the run may not exceed 2 percent of the span value.
(3) Method 9 and the procedures in �60.11 shall be used to determine opacity.
[54 FR 6669, Feb. 14, 1989]
['Air Programs']
['Air Quality']
UPGRADE TO CONTINUE READING
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.