['Air Programs']
['Air Quality']
07/31/2024
...
(a) Your plan must include monitoring, recordkeeping, and reporting requirements for designated facilities. To satisfy this requirement, you have the option of either:
(1) Specifying that sources must report emission and electricity generation data according to part 75 of this chapter; or
(2) Including an alternative monitoring, recordkeeping, and reporting program that includes specifications for the following program elements:
(i) Monitoring plans that specify the monitoring methods, systems, and formulas that will be used to measure CO2 emissions;
(ii) Monitoring methods to continuously and accurately measure all CO2 emissions, CO2 emission rate, and other data necessary to determine compliance or assure data quality;
(iii) Quality assurance test requirements to ensure monitoring systems provide reliable and accurate data for assessing and verifying compliance;
(iv) Recordkeeping requirements;
(v) Electronic reporting procedures and systems; and
(vi) Data validation procedures for ensuring data are complete and calculated consistent with program rules, including procedures for determining substitute data in instances where required data would otherwise be incomplete.
(b) [Reserved]
[84 FR 32582, July 8, 2019]
READ MORESHOW LESS
['Air Programs']
['Air Quality']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.