['Water Programs']
['Water Quality', 'Point Sources', 'Toxic Water Pollutants', 'Water Programs', 'Total Maximum Daily Loads']
02/03/2025
...
(a) Except as provided in §425.04 and 40 CFR 403.7 and §403.13, any existing sources subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403, and achieve the following pretreatment standards:
Pollutant or pollutant property | PSES limitations | |
---|---|---|
Maximum for any 1 day | Maximum for monthly average | |
1 Not less than 7.0. | ||
Milligrams per liter (mg/l) | ||
Sulfide | 24 | -- |
Total Chromium | 12 | 8 |
pH | ( 1) | ( 1) |
(b) Any existing source subject to this subpart which processes less than 350 hides/day shall comply with §425.35(a), except that the Total Chromium limitations contained in §425.35(a) do not apply.
[47 FR 52870, Nov. 23, 1982; 48 FR 36116, June 30, 1983, as amended at 53 FR 9182, Mar. 21, 1988]
READ MORESHOW LESS
['Water Programs']
['Water Quality', 'Point Sources', 'Toxic Water Pollutants', 'Water Programs', 'Total Maximum Daily Loads']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.