['Air Programs']
['Hazardous Air Pollutants']
12/23/2024
...
As stated in §63.8630, you must submit each notification that applies to you according to the following table:
If you . . . | You must . . . | No later than . . . | As specified in . . . |
---|---|---|---|
1. Start up your affected source before December 28, 2015 | Submit an Initial Notification | June 22, 2016, or no later than 120 days after the source becomes subject to this subpart, whichever is later | §63.9(b)(2). |
2. Start up your new or reconstructed affected source on or after December 28, 2015 | Submit an Initial Notification | 120 calendar days after you become subject to this subpart | §63.9(b)(2). |
3. Are required to conduct a performance test | Submit a notification of intent to conduct a performance test | 60 calendar days before the performance test is scheduled to begin | §63.7(b)(1). |
4. Are required to conduct a compliance demonstration that includes a performance test according to the requirements in Table 4 to this subpart | Submit a Notification of Compliance Status, including the performance test results | 60 calendar days following the completion of the performance test, by the close of business | §63.9(h) and §63.10(d)(2). |
5. Are required to conduct a compliance demonstration required in Table 6 to this subpart that does not include a performance test (i.e., compliance demonstrations for the work practice standards) | Submit a Notification of Compliance Status | 30 calendar days following the completion of the compliance demonstrations, by the close of business | §63.9(h). |
6. Request to use the routine control device maintenance alternative standard according to §63.8570(d) | Submit your request | 120 calendar days before the compliance date specified in §63.8545 | |
7. Own or operate an affected kiln that is subject to the work practice standard specified in Item 1 of Table 3 to this subpart, and you intend to use a fuel other than natural gas or equivalent to fire the affected kiln | Submit a notification of alternative fuel use | 48 hours following the declaration of a period of natural gas curtailment or supply interruption, as defined in §63.8665 |
[ 85 FR 73915, Nov. 19, 2020]
READ MORESHOW LESS
['Air Programs']
['Hazardous Air Pollutants']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2024 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.