Tank design capacity (cubic meters) | Maximum HAP vapor pressure of off-site material managed in tank (kilopascals) | Tank control level |
---|---|---|
Design capacity less than 38 m 3 | Maximum HAP vapor pressure less than 76.6 kPa | Level 1. |
Design capacity less than 38 m 3 | Maximum HAP vapor pressure equal to or greater than 76.6 kPa | Level 2, except that fixed roof tanks equipped with an internal floating roof and tanks equipped with an external floating roof as provided for in §63.685(d)(1) and (2) shall not be used. |
Design capacity equal to or greater than 38 m 3 and less than 151 m 3 | Maximum HAP vapor pressure less than 13.1 kPa | Level 1. |
Maximum HAP vapor pressure equal to or greater than 13.1 kPa | Level 2. | |
Design capacity equal to or greater than 151 m 3 | Maximum HAP vapor pressure less than 0.7 kPa | Level 1. |
Maximum HAP vapor pressure equal to or greater than 0.7 kPa | Level 2. |
[80 FR 14283, Mar. 18, 2015]
['Air Programs']
['Hazardous Air Pollutants']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.