Table 3 to Subpart AAAAAAA of Part 63 - Test Methods
| For * * * | You must use * * * |
|---|---|
| a The sampling locations must be located at the outlet of the process equipment (or control device, if applicable), prior to any releases to the atmosphere. b When using EPA Method 23, the toluene extraction step specified in section 3.1.2.1 of the method should be omitted. | |
| 1. Selecting the sampling locations a and the number of traverse points | EPA test method 1 or 1A in appendix A to part 60. |
| 2. Determining the velocity and volumetric flow rate | EPA test method 2, 2A, 2C, 2D, 2F, or 2G, as appropriate, in appendix A to part 60. |
| 3. Determining the gas molecular weight used for flow rate determination | EPA test method 3, 3A, 3B, as appropriate, in appendix A to part 60. |
| 4. Measuring the moisture content of the stack gas | EPA test method 4 in appendix A to part 60. |
| 5. Measuring the PM emissions | EPA test method 5A in appendix A to part 60. |
| 6. Measuring the PAH emissions | EPA test method 23. |
[88 FR 16773, March 20, 2023]
['Air Programs']
['Hazardous Air Pollutants']
UPGRADE TO CONTINUE READING
ezExplanations
Results Aided by AI
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.