H2S content of acid gas (Y), % | Sulfur feed rate (X), LT/D | |||
---|---|---|---|---|
2.0 ≤ X ≤ 5.0 | 5.0 < X ≤ 15.0 | 15.0 < X ≤ 300.0 | X > 300.0 | |
X = The sulfur feed rate from the sweetening unit (i.e., the H2S in the acid gas), expressed as sulfur, Mg/D(LT/D), rounded to one decimal place.
Y = The sulfur content of the acid gas from the sweetening unit, expressed as mole percent H2S (dry basis) rounded to one decimal place. Z = The minimum required sulfur dioxide (SO2) emission reduction efficiency, expressed as percent carried to one decimal place. Zi refers to the reduction efficiency required at the initial performance test. Zc refers to the reduction efficiency required on a continuous basis after compliance with Zi has been demonstrated. | ||||
Y ≥ 50 | 74.0 | 85.35X 0.0144Y 0.0128 or 99.9, whichever is smaller. | ||
20 ≤ Y < 50 | 74.0 | 85.35X 0.0144Y 0.0128 or 97.5, whichever is smaller | 97.5 | |
10 ≤ Y < 20 | 74.0 | 85.35X 0.0144Y 0.0128 or 90.8, whichever is smaller | 90.8 | 90.8 |
Y < 10 | 74.0 | 74.0 | 74.0 | 74.0 |
[78 FR 58447, Sept. 23, 2013]
['Air Programs']
['Air Quality']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.