(a) The following duty cycles apply for constant-speed engines:
(1) The following duty cycle applies for discrete-mode testing:
D2 mode number | Engine speed | Torque (percent) 1 | Weighting factors |
---|---|---|---|
1 | Engine governed | 100 | 0.05 |
2 | Engine governed | 75 | 0.25 |
3 | Engine governed | 50 | 0.30 |
4 | Engine governed | 25 | 0.30 |
5 | Engine governed | 10 | 0.10 |
1 The percent torque is relative to maximum test torque. |
(2) The following duty cycle applies for ramped-modal testing:
RMC mode | Time in mode (seconds) | Engine speed | Torque (percent) 1 2 |
---|---|---|---|
1a Steady-state | 53 | Engine governed | 100. |
1b Transition | 20 | Engine governed | Linear transition. |
2a Steady-state | 101 | Engine governed | 10. |
2b Transition | 20 | Engine governed | Linear transition. |
3a Steady-state | 277 | Engine governed | 75. |
3b Transition | 20 | Engine governed | Linear transition. |
4a Steady-state | 339 | Engine governed | 25. |
4b Transition | 20 | Engine governed | Linear transition. |
5 Steady-state | 350 | Engine governed | 50. |
1 The percent torque is relative to maximum test torque. 2 Advance from one mode to the next within a 20-second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode. |
(b) The following duty cycles apply for variable-speed engines with maximum engine power below 19 kW:
(1) The following duty cycle applies for discrete-mode testing:
G2 mode number | Engine speed 1 | Torque (percent) 2 | Weighting factors |
---|---|---|---|
1 | Maximum test speed | 100 | 0.09 |
2 | Maximum test speed | 75 | 0.20 |
3 | Maximum test speed | 50 | 0.29 |
4 | Maximum test speed | 25 | 0.30 |
5 | Maximum test speed | 10 | 0.07 |
6 | Warm idle | 0 | 0.05 |
1 Speed terms are defined in 40 CFR part 1065. 2 The percent torque is relative to the maximum torque at the commanded test speed. |
(2) The following duty cycle applies for ramped-modal testing:
RMC mode | Time in mode (seconds) | Engine speed 1 3 | Torque (percent) 2 3 |
---|---|---|---|
1a Steady-state | 41 | Warm idle | 0. |
1b Transition | 20 | Linear transition | Linear transition. |
2a Steady-state | 135 | Maximum test speed | 100. |
2b Transition | 20 | Maximum test speed | Linear transition. |
3a Steady-state | 112 | Maximum test speed | 10. |
3b Transition | 20 | Maximum test speed | Linear transition. |
4a Steady-state | 337 | Maximum test speed | 75. |
4b Transition | 20 | Maximum test speed | Linear transition. |
5a Steady-state | 518 | Maximum test speed | 25. |
5b Transition | 20 | Maximum test speed | Linear transition. |
6a Steady-state | 494 | Maximum test speed | 50. |
6b Transition | 20 | Linear transition | Linear transition. |
7 Steady-state | 43 | Warm idle | 0. |
1 Speed terms are defined in 40 CFR part 1065. 2 The percent torque is relative to the maximum torque at the commanded engine speed. 3 Advance from one mode to the next within a 20-second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting. |
(c) The following duty cycles apply for variable-speed engines with maximum engine power at or above 19 kW:
(1) The following duty cycle applies for discrete-mode testing:
C1 mode number | Engine speed 1 | Torque (percent) 2 | Weighting factors |
---|---|---|---|
1 | Maximum test speed | 100 | 0.15 |
2 | Maximum test speed | 75 | 0.15 |
3 | Maximum test speed | 50 | 0.15 |
4 | Maximum test speed | 10 | 0.10 |
5 | Intermediate test speed | 100 | 0.10 |
6 | Intermediate test speed | 75 | 0.10 |
7 | Intermediate test speed | 50 | 0.10 |
8 | Warm idle | 0 | 0.15 |
1 Speed terms are defined in 40 CFR part 1065. 2 The percent torque is relative to the maximum torque at the commanded test speed. |
(2) The following duty cycle applies for ramped-modal testing:
RMC mode | Time in mode (seconds) | Engine speed 1 3 | Torque (percent) 2 3 |
---|---|---|---|
1a Steady-state | 126 | Warm Idle | 0. |
1b Transition | 20 | Linear Transition | Linear Transition. |
2a Steady-state | 159 | Intermediate Speed | 100. |
2b Transition | 20 | Intermediate Speed | Linear Transition. |
3a Steady-state | 160 | Intermediate Speed | 50. |
3b Transition | 20 | Intermediate Speed | Linear Transition. |
4a Steady-state | 162 | Intermediate Speed | 75. |
4b Transition | 20 | Linear Transition | Linear Transition. |
5a Steady-state | 246 | Maximum Test Speed | 100. |
5b Transition | 20 | Maximum Test Speed | Linear Transition. |
6a Steady-state | 164 | Maximum Test Speed | 10. |
6b Transition | 20 | Maximum Test Speed | Linear Transition. |
7a Steady-state | 248 | Maximum Test Speed | 75. |
7b Transition | 20 | Maximum Test Speed | Linear Transition. |
8a Steady-state | 247 | Maximum Test Speed | 50. |
8b Transition | 20 | Linear Transition | Linear Transition. |
9 Steady-state | 128 | Warm Idle | 0. |
1 Speed terms are defined in 40 CFR part 1065. 2 The percent torque is relative to the maximum torque at the commanded engine speed. 3 Advance from one mode to the next within a 20-second transition phase. During the transition phase, command a linear progression from the torque setting of the current mode to the torque setting of the next mode, and simultaneously command a similar linear progression for engine speed if there is a change in speed setting. |
[69 FR 39213, June 29, 2004, as amended at 73 FR 37241, June 30, 2008]
READ MORESHOW LESS
['Air Programs']
['Air Emissions']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.