(a) The collector must be present and maintain visual contact with the employee during the procedures outlined in this section.
(1) As the oral fluid collector, you must not allow any person other than you, the employee, or a DOT agency representative to actually witness the testing process. [Change Notice]
(2) [Reserved] [Change Notice]
(b) The collector must note any unusual behavior or appearance of the employee on the CCF. If the collector detects any conduct that clearly indicates an attempt to tamper with a specimen (e.g., an attempt to bring into the collection site an adulterant or oral fluid substitute), the collector must terminate the collection and report the information to the DER so that the employer can decide whether to deem the situation a refusal.
(c) The employee and collector must complete the specimen collection in accordance with the manufacturer’s instructions for the collection device.
(1) Under the observation of the collector, the employee is responsible for positioning the specimen collection device for collection.
(2) The collector must ensure the collection is performed correctly ( i.e., using the oral fluid device in the manner described by its manufacturer), that the collection device is working properly, and that a sufficient specimen volume is collected. After the employee provides a sufficient specimen, check the “Volume Indicator(s) Observed” box in Step 2 of the Federal CCF to document that you observed the volume indicator(s) during the collection. [Change Notice] [Previous Text]
(3) If the employee states that he or she is unable to provide an oral fluid specimen or provides an insufficient specimen during the collection process, the collector must continue to make one attempt to collect, after an insufficient specimen, the collector follows the procedure in §40.193.
(4) The collector must inspect the specimen for unusual color, presence of foreign objects or material, or other signs of tampering. If it is apparent from this inspection that the employee has tampered with the specimen, the collector must conduct a new collection.
(i) Document any unusual characteristics referenced above in the Remarks section of the CCF.
(ii) Proceed with obtaining the new oral fluid specimen from the donor. Note on the new CCF that this is another collection for the same testing event (i.e., Document in the remarks section that this is Specimen 2 of 2 and include the Specimen ID number of the other specimen). Make the same notation on the CCF of the suspect specimen.
[88 FR 27641, May 2, 2023; 89 FR 51986, June 21, 2024; 89 FR 62665, Aug. 1, 2024; 89 FR 87798, Nov. 5, 2024]
READ MORESHOW LESS
['Drug and Alcohol Testing - DOT']
['Designated employer representative (DER) - Motor Carrier', 'Drug testing - Motor Carrier', 'Medical review officer (MRO) - Motor Carrier']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2024 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.