2.29 (1) When a substance is known to be included in Class 6.1 and that knowledge is based on documentary evidence published in technical journals or government publications and testing is not done to determine the packing group, the substance must be included in Packing Group I.
(2) Substances that are included in Class 6.1 due to
(a) oral toxicity are included in one of the following packing groups:
(i) Packing Group I, if the LD50 (oral) is less than or equal to 5 mg/kg,
(ii) Packing Group II, if the LD50 (oral) is greater than 5 mg/kg but less than or equal to 50 mg/kg, or
(iii) Packing Group III, if the LD50 (oral) is greater than 50 mg/kg but less than or equal to 300 mg/kg;
(b) dermal toxicity are included in one of the following packing groups:
(i) Packing Group I if the LD50 (dermal) is less than or equal to 50 mg/kg,
(ii) Packing Group II if the LD50 (dermal) is greater than 50 mg/kg but less than or equal to 200 mg/kg, or
(iii) Packing Group III if the LD50 (dermal) is greater than 200 mg/kg but less than or equal to 1 000 mg/kg;
(c) inhalation toxicity by dust or mist are included in one of the following packing groups:
(i) Packing Group I if the LC50 (inhalation) is less than or equal to 0.2 mg/L,
(ii) Packing Group II if the LC50 (inhalation) is greater than 0.2 mg/L but less than or equal to 2 mg/L, or
(iii) Packing Group III if the LC50 (inhalation) is greater than 2 mg/L but less than or equal to 4 mg/L; or
(d) inhalation toxicity by vapour are included in one of the following packing groups, where “V” is the saturated vapour concentration in millilitres per cubic metre of air at 20°C and at 101.3 kPa:
(i) Packing Group I, if
(A) V is greater than or equal to 10 multiplied by the LC50, and
(B) the LC50 is less than or equal to 1,000 mL/m3,
(ii) Packing Group II, if
(A) V is greater than or equal to the LC50,
(B) the LC50 is less than or equal to 3,000 mL/m3, and
(C) the criteria for Packing Group I are not met, or
(iii) Packing Group III, if
(A) V is greater than or equal to 0.2 multiplied by the LC50,
(B) the LC50 is less than or equal to 5,000 mL/m3, and
(C) the criteria for inclusion in Packing Group I or II are not met.
SOR/2008-34, s. 35; SOR/2012-245, s. 16(E)
['Dangerous goods']
['Classification - Dangerous Goods']
UPGRADE TO CONTINUE READING
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.