['Air Programs']
['Air Emissions']
10/12/2023
...
The following requirements apply for any nozzle installation used for dispensing gasoline into motor vehicles:
(a) Nozzles must meet the following hardware specifications:
(1) The outside diameter of the terminal end must not be greater than 21.3 mm.
(2) The terminal end must have a straight section of at least 63 mm.
(3) The retaining spring must terminate at least 76 mm from the terminal end.
(b) The dispensing flow rate must not exceed a maximum value of 10 gallons per minute. The flow rate may be controlled through any means in the pump/dispenser system, as long as it does not exceed the specified maximum value.
[85 FR 78469, Dec. 4, 2020; 88 FR 4718, Jan. 24, 2023]
READ MORESHOW LESS
['Air Programs']
['Air Emissions']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.