In addition to §179.100, the individual specification requirements are as follows:
DOT specification | Insulation | Bursting pressure (psig) | Minimum plate thickness (inches) | Test pressure (psig) | Manway cover thickness | Bottom outlet | Bottom washout | Reference (179.***) |
---|---|---|---|---|---|---|---|---|
1When steel of 65,000 to 81,000 p.s.i. minimum tensile strength is used, the thickness of plates shall be not less than 5/8 inch, and when steel of 81,000 p.s.i. minimum tensile strength is used, the minimum thickness of plate shall be not less than 9/16 inch | ||||||||
2When approved material other than aluminum alloys are used, the thickness shall be not less than 2 1/4 inches. | ||||||||
3When steel of 65,000 p.s.i. minimum tensile strength is used, minimum thickness of plates shall be not less than 1/2 inch. | ||||||||
4Tank cars not equipped with a thermal protection or an insulation system used for the transportation of a Class 2 (compressed gas) material must have at least the upper two-thirds of the exterior of the tank, including manway nozzle and all appurtenances in contact with this area, finished with a reflective coat of white paint. | ||||||||
5For inside diameter of 87 inches or less, the thickness of plates shall be not less than 1/2 inch. | ||||||||
6See AAR Specifications for Tank Cars, appendix E, E4.01 (IBR, see §171.7 of this subchapter), and §179.103-2. | ||||||||
7When the use of nickel is required by the lading, the thickness shall not be less than two inches. | ||||||||
105A100ALW | Yes | 500 | 5/8 | 100 | 221/2 | No | No. | |
105A200ALW | Yes | 500 | 5/8 | 200 | 221/2 | No | No. | |
105A300ALW | Yes | 750 | 5/8 | 300 | 225/8 | No | No. | |
105A100W | Yes | 500 | 39/16 | 100 | 21/4 | No | No. | |
105A200W | Yes | 500 | 39/16 | 200 | 21/4 | No | No. | |
105A300W | Yes | 750 | 111/16 | 300 | 721/4 | No | No. | |
105A400W | Yes | 1,000 | 111/16 | 400 | 721/4 | No | No. | |
105A500W | Yes | 1,250 | 111/16 | 500 | 21/4 | No | No | 102-1, 102-2. |
105A600W | Yes | 1,500 | 111/16 | 600 | 21/4 | No | No | 102-4, 102-17. |
109A100ALW | Optional | 500 | 5/8 | 100 | 221/2 | No | Optional. | |
109A200ALW | Optional | 500 | 5/8 | 200 | 221/2 | No | Optional. | |
109A300ALW | Optional | 750 | 5/8 | 300 | 225/8 | No | Optional. | |
109A300W | Optional | 500 | 111/16 | 300 | 21/4 | No | Optional. | |
112A200W | Optional4 | 500 | 3,59/16 | 200 | 21/4 | No | No. | |
112A340W | Optional4 | 850 | 111/16 | 340 | 21/4 | No | No. | |
112A400W | Optional4 | 1,000 | 111/16 | 400 | 21/4 | No | No. | |
112A500W | Optional4 | 1,250 | 111/16 | 500 | 21/4 | No | No. | |
114A340W | Optional4 | 850 | 111/16 | 340 | 6 | Optional | Optional | 103. |
114A400W | Optional4 | 1,000 | 111/16 | 400 | 6 | Optional | Optional | 103. |
120A200ALW | Yes | 500 | 5/8 | 200 | 221/2 | Optional | Optional | 103. |
120A100W | Yes | 500 | 39/16 | 100 | 21/4 | Optional | Optional | 103. |
120A200W | Yes | 500 | 39/16 | 200 | 21/4 | Optional | Optional | 103. |
120A300W | Yes | 750 | 111/16 | 300 | 21/4 | Optional | Optional | 103. |
120A400W | Yes | 1,000 | 111/16 | 400 | 21/4 | Optional | Optional | 103. |
120A500W | Yes | 1,250 | 111/16 | 500 | 21/4 | Optional | Optional | 103. |
[Amdt. 179–52, 61 FR 28679, June 5, 1996 as amended at 66 FR 45390, Aug. 28, 2001; 68 FR 75760, Dec. 31, 2003]
['General Packaging Requirements - Hazmat']
['General Packaging Requirements - Hazmat']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.