Summary of Decisions
Refrigeration and Air Conditioning Sector Acceptable Subject to Use Conditions
R-406A/“GHG”/“McCool”, “GHG-HP”, “GHG-X4”/“Autofrost”/“Chill-It”, and “Hot Shot”/“Kar Kool” are acceptable substitutes for CFC-12 in retrofitted motor vehicle air conditioning systems (MVACs) subject to the use condition that a retrofit to these refrigerants must include replacing non-barrier hoses with barrier hoses.
For all refrigerants submitted for use in motor vehicle air conditioning systems, subsequent to the effective date of this FRM, in addition to the information previously required in the March 18, 1994 final SNAP rule (58 FR 13044), SNAP submissions must include specifications for the fittings similar to those found in SAE J639, samples of all fittings, and the detailed label described below at the same time as the initial SNAP submission, or the submission will be considered incomplete. Under section 612 of the Clean Air Act, substitutes for which submissions are incomplete may not be sold or used, regardless of other acceptability determinations, and the prohibition against sale of a new refrigerant will not end until 90 days after EPA determines the submission is complete.
In addition, the use of a) R-406A/“GHG”/“McCool”, “HCFC Blend Lambda”/“GHG-HP”, R-414A/“HCFC Blend Xi”/“GHG-X4/“Autofrost”/“Chill-It”, R-414B/“Hot Shot”/“Kar Kool”, and R-416A/“HCFC Blend Beta”/“FREEZE 12” as CFC-12 substitutes in retrofitted MVACs, and b) all refrigerants submitted for, and listed in, subsequent Notices of Acceptability as substitutes for CFC-12 in MVACs, must meet the following conditions.
1. Each refrigerant may only be used with a set of fittings that is unique to that refrigerant. These fittings (male or female, as appropriate) must be designed by the manufacturer of the refrigerant. The manufacturer is responsible to ensure that the fittings meet all of the requirements listed below, including testing according to SAE standards. These fittings must be designed to mechanically prevent cross-charging with another refrigerant, including CFC-12.
The fittings must be used on all containers of the refrigerant, on can taps, on recovery, recycling, and charging equipment, and on all air conditioning system service ports. A refrigerant may only be used with the fittings and can taps specifically intended for that refrigerant and designed by the manufacturer of the refrigerant. Using a refrigerant with a fitting designed by anyone else, even if it is different from fittings used with other refrigerants, is a violation of this use condition. Using an adapter or deliberately modifying a fitting to use a different refrigerant is a violation of this use condition.
Fittings shall meet the following criteria, derived from Society of Automotive Engineers (SAE) standards and recommended practices:
a. When existing CFC-12 service ports are retrofitted, conversion assemblies shall attach to the CFC-12 fitting with a thread lock adhesive and/or a separate mechanical latching mechanism in a manner that permanently prevents the assembly from being removed.
b. All conversion assemblies and new service ports must satisfy the vibration testing requirements of section 3.2.1 or 3.2.2 of SAE J1660, as applicable, excluding references to SAE J639 and SAE J2064, which are specific to HFC-134a.
c. In order to prevent discharge of refrigerant to the atmosphere, systems shall have a device to limit compressor operation before the pressure relief device will vent refrigerant.
d. All CFC-12 service ports not retrofitted with conversion assemblies shall be rendered permanently incompatible for use with CFC-12 related service equipment by fitting with a device attached with a thread lock adhesive and/or a separate mechanical latching mechanism in a manner that prevents the device from being removed.
2. When a retrofit is performed, a label must be used as follows:
a. The person conducting the retrofit must apply a label to the air conditioning system in the engine compartment that contains the following information:
i. The name and address of the technician and the company performing the retrofit.
ii. The date of the retrofit.
iii. The trade name, charge amount, and, when applicable, the ASHRAE refrigerant numerical designation of the refrigerant.
iv. The type, manufacturer, and amount of lubricant used.
v. If the refrigerant is or contains an ozone-depleting substance, the phrase “ozone depleter”.
vi. If the refrigerant displays flammability limits as measured according to ASTM E681, the statement “This refrigerant is FLAMMABLE. Take appropriate precautions.”
b. The label must be large enough to be easily read and must be permanent.
c. The background color must be unique to the refrigerant.
d. The label must be affixed to the system over information related to the previous refrigerant, in a location not normally replaced during vehicle repair.
e. In accordance with SAE J639, testing of labels must meet ANSI/UL 969-1991.
f. Information on the previous refrigerant that cannot be covered by the new label must be rendered permanently unreadable.
3. No substitute refrigerant may be used to “top-off” a system that uses another refrigerant. The original refrigerant must be recovered in accordance with regulations issued under section 609 of the CAA prior to charging with a substitute.
Application | Substitute | Decision | Conditions | Comments |
---|---|---|---|---|
Electronics Cleaning w/CFC-113 and MCF | HFC-4310mee | Acceptable | Subject to a 200 ppm time-weighted average workplace exposure standard and a 400 ppm workplace exposure ceiling | |
Precision Cleaning w/CFC-113 and MCF | HFC-4310mee | Acceptable | Subject to a 200 ppm time-weighted average workplace exposure standard and a 400 ppm workplace exposure ceiling |
Application | Substitute | Decision | Comments |
---|---|---|---|
Electronics Cleaning w/CFC-113 and MCF | Perfluoropolyethers | Perfluoropolyethers are acceptable substitutes for CFC-113 and MCF in the precision cleaning sector for high performance, precision-engineered applications only where reasonable efforts have been made to ascertain that other alternatives are not technically feasible due to performance or safety requirements | PFPEs have similar global warming profile to the PFCs, and the SNAP decision on PFPEs parallels that for PFCs. |
Precision Cleaning w/CFC-113 and MCF | Perfluoropolyethers | Perfluoropolyethers are acceptable substitutes for CFC-113 and MCF in the precision cleaning sector for high performance, precision-engineered applications only where reasonable efforts have been made to ascertain that other alternatives are not technically feasible due to performance or safety requirements | PFPEs have similar global warming profile to the PFCs, and the SNAP decision on PFPEs parallels that for PFCs. |
End-use | Substitute | Decision | Comments |
---|---|---|---|
Electronics Cleaning w/CFC-113 and MCF | HCFC-141b | Extension of existing unacceptability determination to grant existing uses in high-performance electronics permission to continue until January 1, 1997 | This determination extends the use date for HCFC-141b in solvent cleaning, but only for existing users in high-performance electronics and only for one year. |
Precision Cleaning w/CFC-113 and MCF | HCFC-141b | Extension of existing unacceptability determination to grant existing uses in precision cleaning permission to continue until January 1, 1997 | This determination extends the use date for HCFC-141b in solvent cleaning, but only for existing users in precision cleaning and only for one year. |
Application | Substitute | Decision | Comments |
---|---|---|---|
CFC-113, MCF, and HCFC-141b as aerosol solvents | Perfluorocarbons | Perfluorocarbons are acceptable substitutes for aerosol applications only where reasonable efforts have been made to ascertain that other alternatives are not technically feasible due to performance or safety requirements | PFCs have extremely long atmospheric lifetimes and high Global Warming Potentials. This decision reflects these concerns and is patterned after the SNAP decision on PFCs in the solvent cleaning sector. |
Perfluoropolyethers | Perfluorocarbons are acceptable substitutes for aerosol applications only where reasonable efforts have been made to ascertain that other alternatives are not technically feasible due to performance or safety requirements | PFPEs have similar global warming profile to the PFCs, and the SNAP decision on PFPEs parallels that for PFCs in the solvent cleaning sector. |
End-use | Substitute | Decision | Comments |
---|---|---|---|
CFC-11, CFC-12, HCFC-22, and HCFC-142b as aerosol propellants | SF6 | Unacceptable | SF6 has the highest GWP of all industrial gases, and other compressed gases meet user needs in this application equally well. |
[61 FR 54040, Oct. 16, 1996, as amended at 80 FR 42953, July 20, 2015]
READ MORESHOW LESS
['Air Programs']
['Ozone Layer Protection']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.