['Air Programs']
['Air Quality']
11/20/2023
...
§60.240 Applicability and designation of affected facility.
(a) The affected facility to which the provisions of this subpart apply is each granular triple superphosphate storage facility. For the purpose of this subpart, the affected facility includes any combination of: Storage or curing piles, conveyors, elevators, screens and mills.
(b) Any facility under paragraph (a) of this section that commences construction or modification after October 22, 1974, is subject to the requirements of this subpart.
[42 FR 37938, July 25, 1977]
§60.241 Definitions.
As used in this subpart, all terms not defined herein shall have the meaning given them in the Act and in subpart A of this part.
(a) Granular triple superphosphate storage facility means any facility curing or storing fresh granular triple superphosphate.
(b) Total fluorides means elemental fluorine and all fluoride compounds as measured by reference methods specified in §60.244, or equivalent or alternative methods.
(c) Equivalent P2O5stored means the quantity of phosphorus, expressed as phosphorus pentoxide, being cured or stored in the affected facility.
(d) Fresh granular triple superphosphate means granular triple superphosphate produced within the preceding 72 hours.
[40 FR 33156, Aug. 6, 1975, as amended at 62 FR 18280, Apr. 15, 1997; 65 FR 61757, Oct. 17, 2000]
§60.242 Standard for fluorides.
(a) On and after the date on which the performance test required to be conducted by §60.8 is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility any gases which contain total fluorides in excess of 0.25 g/hr/megagram (Mg) of equivalent P2O5 stored (5.0 × 10 −4 lb/hr/ton of equivalent P2O5 stored).
(b) No owner or operator subject to the provisions of this subpart shall ship fresh granular triple superphosphate from an affected facility.
[40 FR 33156, Aug. 6, 1975, as amended at 62 FR 18280, Apr. 15, 1997; 65 FR 61757, Oct. 17, 2000]
§60.243 Monitoring of operations.
(a) The owner or operator of any granular triple superphosphate storage facility subject to the provisions of this subpart shall maintain an accurate account of triple superphosphate in storage to permit the determination of the amount of equivalent P2O5 stored.
(b) The owner or operator of any granular triple superphosphate storage facility subject to the provisions of this subpart shall maintain a daily record of total equivalent P2O5 stored by multiplying the percentage P2O5 content, as determined by §60.244(c)(3), times the total mass of granular triple superphosphate stored.
(c) Except as specified in paragraph (e) of this section, the owner or operator of any granular triple superphosphate storage facility subject to the provisions of this subpart shall install, calibrate, maintain, and operate a monitoring device that continuously measures and permanently records the total pressure drop across any absorber. The monitoring device shall have an accuracy of ±5 percent over its operating range.
(d) The owner or operator of any granular triple superphosphate storage facility subject to the provisions of this subpart shall develop for approval by the Administrator a site-specific methodology including sufficient recordkeeping for the purposes of demonstrating compliance with §60.242 (b).
(e) Any facility under §60.240(a) that commences construction, modification, or reconstruction after November 7, 2014 is subject to the requirements of this paragraph instead of the requirements in paragraph (c) of this section. If an absorber is used to comply with §60.232, then the owner or operator shall continuously monitor pressure drop through the absorber and meet the requirements specified in paragraphs (e)(1) through (4) of this section.
(1) The owner or operator shall install, calibrate, maintain, and operate a continuous monitoring system (CMS) that continuously measures and permanently records the pressure at the gas stream inlet and outlet of the absorber. The pressure at the gas stream inlet of the absorber may be measured using amperage on the blower if a correlation between pressure and amperage is established.
(2) The CMS must have an accuracy of ±5 percent over the normal range measured or 0.12 kilopascals (0.5 inches of water column), whichever is greater.
(3) The owner or operator shall establish an allowable range for the pressure drop through the absorber. The allowable range is ±20 percent of the arithmetic average of the three test runs conducted during the performance test required in §60.8. The Administrator retains the right to reduce the ±20 percent adjustment to the baseline average values of operating ranges in those instances where performance test results indicate that a source's level of emissions is near the value of an applicable emissions standard. However, the adjustment must not be reduced to less than ±10 percent under any instance.
(4) The owner or operator shall demonstrate continuous compliance by maintaining the daily average pressure drop through the absorber to within the allowable range established in paragraph (e)(3) of this section. The daily average pressure drop through the absorber for each operating day shall be calculated using the data recorded by the monitoring system. If the emissions unit operation is continuous, the operating day is a 24-hour period. If the emissions unit operation is not continuous, the operating day is the total number of hours of control device operation per 24-hour period. Valid data points must be available for 75 percent of the operating hours in an operating day to compute the daily average.
[40 FR 33156, Aug. 6, 1975, as amended at 54 FR 6671, Feb. 14, 1989; 62 FR 18280, Apr. 15, 1997; 80 FR 50435, Aug. 19, 2015]
§60.244 Test methods and procedures.
(a) The owner or operator shall conduct performance tests required in §60.8 only when the following quantities of product are being cured or stored in the facility.
(1) Total granular triple superphosphate is at least 10 percent of the building capacity, and
(2) Fresh granular triple superphosphate is at least 6 percent of the total amount of triple superphosphate, or
(3) If the provision in paragraph (a)(2) of this section exceeds production capabilities for fresh granular triple superphosphate, fresh granular triple superphosphate is equal to at least 5 days maximum production.
(b) In conducting the performance tests required in §60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in §60.8(b).
(c) The owner or operator shall determine compliance with the total fluorides standard in §60.242 as follows:
(1) The emission rate (E) of total fluorides shall be computed for each run using the following equation:
where:
E = emission rate of total fluorides, g/hr/Mg (lb/hr/ton) of equivalent P2O5 stored.
Csi = concentration of total fluorides from emission point “i,” mg/dscm (gr/dscf).
Qsdi = volumetric flow rate of effluent gas from emission point “i,” dscm/hr (dscf/hr).
N = number of emission points in the affected facility.
P = equivalent P2O5 stored, metric tons (tons).
K = conversion factor, 1000 mg/g (7,000 gr/lb).
(2) Method 13A or 13B shall be used to determine the total fluorides concentration (Csi) and volumetric flow rate (Qsdi) of the effluent gas from each of the emission points. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).
(3) The equivalent P2O5 feed rate (P) shall be computed for each run using the following equation:
P = Mp Rp
where:
Mp = amount of product in storage, Mg (ton).
Rp = P2O5 content of product in storage, weight fraction.
(i) The accountability system of §60.243(a) shall be used to determine the amount of product (Mp) in storage.
(ii) The Association of Official Analytical Chemists (AOAC) Method 9 (incorporated by reference - see §60.17) shall be used to determine the P2O5 content (Rp) of the product in storage.
[54 FR 6671, Feb. 14, 1989, as amended at 62 FR 18280, Apr. 15, 1997; 65 FR 61757, Oct. 17, 2000]
§60.245 Recordkeeping.
Any facility under §60.240(a) that commences construction, modification, or reconstruction after November 7, 2014 is subject to the requirements of this section. You must maintain the records identified as specified in §60.7(f) and in paragraphs (a) and (b) of this section. All records required by this subpart must be maintained onsite for at least 5 years.
(a) Records of the daily average pressure drop through the absorber.
(b) Records of deviations. A deviation is determined to have occurred when the monitoring data or lack of monitoring data result in any one of the criteria specified in paragraphs (b)(1) and (2) of this section being met.
(1) A deviation occurs when the daily average value of a monitored operating parameter is less than the minimum pressure drop, or greater than the maximum pressure drop established in §60.243(e)(3).
(2) A deviation occurs when the monitoring data are not available for at least 75 percent of the operating hours in a day.
[80 FR 50436, Aug. 19, 2015]
READ MORESHOW LESS
['Air Programs']
['Air Quality']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.
Copyright 2024 J. J. Keller & Associate, Inc. For re-use options please contact copyright@jjkeller.com or call 800-558-5011.