If you elect to install and certify a NOX-diluent CEMS under �60.4345, then the initial performance test required under �60.8 may be performed in the following alternative manner:
(a) Perform a minimum of nine RATA reference method runs, with a minimum time per run of 21 minutes, at a single load level, within plus or minus 25 percent of 100 percent of peak load. The ambient temperature must be greater than 0�F during the RATA runs.
(b) For each RATA run, concurrently measure the heat input to the unit using a fuel flow meter (or flow meters) and measure the electrical and thermal output from the unit.
(c) Use the test data both to demonstrate compliance with the applicable NOX emission limit under �60.4320 and to provide the required reference method data for the RATA of the CEMS described under �60.4335.
(d) Compliance with the applicable emission limit in �60.4320 is achieved if the arithmetic average of all of the NOX emission rates for the RATA runs, expressed in units of ppm or lb/MWh, does not exceed the emission limit.
READ MORESHOW LESS
['Air Programs']
['Air Quality']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.