['Air Programs']
['Air Emissions']
10/12/2023
...
(a) General procedures. An independent surveyor must meet the following requirements:
(1) Electronically submit any plans, notifications, or reports required under this part using forms and procedures specified by EPA.
(2) For each report required under this section, affirm that the survey was conducted in accordance with an EPA-approved survey plan and that the survey results are accurate.
(3) Include EPA-issued company identifiers on each report required under this section.
(4) Submit quarterly reports required under paragraphs (b) and (d) of this section by the following deadlines:
Calendar quarter | Time period covered | Quarterly report deadline |
---|---|---|
Quarter 1 | January 1-March 31 | June 1. |
Quarter 2 | April 1-June 30 | September 1. |
Quarter 3 | July 1-September 30 | December 1. |
Quarter 4 | October 1-December 31 | March 31. |
(b) NFSP quarterly reporting. An independent surveyor conducting the NFSP under §1090.1405 must submit the following information quarterly, as applicable:
(1) For each retail outlet sampled by the independent surveyor:
(i) The identification information for the retail outlet, as assigned by the surveyor in a consistent manner and as specified in the survey plan.
(ii) The displayed fuel manufacturer brand name at the retail outlet, if any.
(iii) The physical location (i.e., address) of the retail outlet.
(2) For each gasoline sample collected by the independent surveyor:
(i) A description of the labeling of the fuel dispenser(s) (e.g., “E0”, “E10”, “E15”, etc.) from which the independent surveyor collected the sample.
(ii) The date and time the independent surveyor collected the sample.
(iii) The test results for the sample, and the test methods used, as determined by the independent surveyor, including the following parameters:
(A) The oxygen content, in weight percent.
(B) The type and amount of each oxygenate, by weight and volume percent.
(C) The sulfur content, in ppm.
(D) The benzene content, in volume percent.
(E) The specific gravity.
(F) The RVP in psi, if tested.
(G) The aromatic content in volume percent, if tested.
(H) The olefin content in volume percent, if tested.
(I) The distillation parameters, if tested.
(3) For each diesel sample collected at a retail outlet by the independent surveyor:
(i) A description of the labeling of the fuel dispenser(s) (e.g., “ULSD”) from which the independent surveyor collected the sample.
(ii) The date and time the independent surveyor collected the sample.
(iii) The tested sulfur content of the sample, and the test method used, as determined by the independent surveyor, in ppm.
(4) Any other information as EPA may require in order to administer reporting systems.
(c) NFSP annual reporting. An independent surveyor conducting the NFSP under §1090.1405 must submit the following information annually by March 31.
(1) An identification of the parties that participated in the survey during the compliance period.
(2) An identification of each geographic area included in a survey.
(3) Summary statistics for each identified geographic area, including the following:
(i) The number of samples collected and tested.
(ii) The mean, median, and range expressed in appropriate units for each measured gasoline and diesel parameter.
(iii) The standard deviation for each measured gasoline and diesel parameter.
(iv) The estimated compliance rate for each measured gasoline and diesel parameter subject to a per-gallon standard in subpart C or D of this part.
(v) A summary of potential non-compliance issues.
(4) Any other information as EPA may require in order to administer reporting systems.
(d) NSTOP quarterly reporting. An independent surveyor conducting the NSTOP under §1090.1450 must submit the following information quarterly, as applicable:
(1) For each gasoline manufacturing facility sampled by the independent surveyor:
(i) The EPA-issued company and facility identifiers for the gasoline manufacturer and the gasoline manufacturing facility.
(2) For each gasoline sample collected by the independent surveyor:
(i) The designation of the gasoline.
(ii) The date and time the independent surveyor collected the sample.
(iii) The batch number or the sample identification number as assigned by the independent surveyor in a consistent manner and as specified in the survey plan.
(iv) A description of any instance in which the gasoline manufacturer did not follow the applicable sampling procedures.
(v) The test results for the sample, and the test methods used, as determined by the independent surveyor, including the following parameters:
(A) The sulfur content, in ppm.
(B) The benzene content, in volume percent.
(C) The RVP in psi, if tested.
(vi) The test results for the sample, and the test methods used, as determined by the gasoline manufacturer, including the following parameters:
(A) The sulfur content, in ppm.
(B) The benzene content, in volume percent.
(C) The RVP in psi, if tested.
(vii) If available, the test results for the sample, and the test methods used, as determined by EPA's National Vehicle and Fuel Emissions Laboratory, including the following parameters:
(A) The sulfur content, in ppm.
(B) The benzene content, in volume percent.
(C) The RVP in psi, if tested.
(viii) The determined site precision under §1090.1450(c)(10)(i) and the test performance index under §1090.1450(c)(10)(ii) for each method and instrument that the gasoline manufacturer used to test the sample.
(ix) The reproducibility of each method that the gasoline manufacturer used to test the sample.
(x) Any applicable correlation equations used to compare the gasoline manufacturer's test results to the independent surveyor's test results.
(3) Any other information as EPA may require in order to administer reporting systems.
[85 FR 78469, Dec. 4, 2020]
READ MORESHOW LESS
['Air Programs']
['Air Emissions']
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.