(a) Test procedures.(1) The contact resistance through each firing line terminal shall be determined.
(2) A 10-pound pull shall be applied to a No. 18 gauge wire that has been connected to each firing line terminal according to the manufacturer's instructions.
(b) Acceptable performance.(1) The contact resistance shall not be greater than 1 ohm.
(2) The No. 18 gauge wire shall not become disconnected from either firing line terminal.
['Specialized Industries']
['Mining']
UPGRADE TO CONTINUE READING
Load More
J. J. Keller is the trusted source for DOT / Transportation, OSHA / Workplace Safety, Human Resources, Construction Safety and Hazmat / Hazardous Materials regulation compliance products and services. J. J. Keller helps you increase safety awareness, reduce risk, follow best practices, improve safety training, and stay current with changing regulations.