Except as provided by 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BAT:
(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:
Regulated parameter | Maximum daily 1 | Maximum monthly avg. 1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
1 mg/L (ppm). |
(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the following effluent limitations:
Regulated parameter | Maximum daily 1 | Maximum monthly avg. 1 |
---|---|---|
Ammonia (as N) | 8.0 | 4.0 |
Total Nitrogen | 194 | 134 |